2. Special function block/unit
Model
Special function block
FX
-1PG(-E)
2N
FX
-10PG
2N
FX
-20SSC-H
3U
Special function unit
FX
-10GM
2N
FX
-20GM
2N
*1.
Do not exceed the maximum rotation speed of the servo motor or the stepping motor.
*2.
Only FX
3U
Refer to the manual of each product.
*2
Frequency
Number of
*1
axes
(Hz)
1-axis
10 to 100,000
1-axis
1 to 1,000,000
2-axes
(independent/
1 to 50,000,000
interpolation)
1-axis
1 to 200,000
2-axes
(independent/
1 to 200,000
interpolation)
and FX
PLC can be connected to the above models.
3UC
1.2 Introduction of Products Needed for Positioning
Output
Unit
system
pulse
Open
"Pulse train + direction" method or
µm
collector
"forward/reverse rotation pulse train"
-4
10
inch
system
mdeg
pulse
Differential
"Pulse train + direction" method or
µm
line driver
"forward/reverse rotation pulse train"
-4
10
inch
system
mdeg
pulse
µm
-4
10
inch
mdeg
pulse
Open
"Pulse train + direction" method or
µm
collector
"forward/reverse rotation pulse train"
-4
10
inch
system
mdeg
pulse
Open
"Pulse train + direction" method or
µm
collector
"forward/reverse rotation pulse train"
-4
10
inch
system
mdeg
1 Introduction
Output method
method
method
SSCNET III
method
method
A - 5
A
B
Apx.