Various Special Relays for Operation Commands

4.3.1

Forward Rotation Limit and Reverse Rotation Limit

When using the servo motor, the forward rotation limit and the reverse rotation limit can be set for the servo
amplifier.
To use the DOG search function for zero return, or to set the forward rotation limit or the reverse rotation limit
for operations other than zero return using the PLC, set the forward rotation limit 1 (LSF) and reverse rotation
limit 1 (LSR) for the PLC so that these limit switches can be activated before the forward rotation limit 2 or
reverse rotation limit 2 of the servo amplifier.
As shown in the following figure, interlock the forward rotation limit 1 (LSF) with the forward limit relay, and the
reverse rotation limit 1 (LSR) with the reverse limit relay. If the forward limit relay or the reverse limit relay turns
ON, the motor will perform operation depending on the output instruction as shown in the following table.
Reverse rotation limit 2
(Servo amplifier side)
Servo motor
Forward rotation limit 1
Reverse rotation limit 1
Use the relays shown in the following table to determine the forward rotation limit and the reverse rotation limit
for each pulse output destination device (Y000, Y001, Y002, Y003).
Pulse output
destination
device
Y000
Y001
*1
Y002
*2
Y003
*1.
Y002 (pulse output destination) cannot be specified when the 14-point or 24-point type FX
connected.
*2.
Devices related to Y003 (pulse output destination) are only valid if two FX
connected to the FX
*3.
M8338 is supported in the FX
and its version is below Ver.2.20, the PLSV instruction will perform operation in the M8338 = OFF
mode (will perform operation without acceleration/deceleration).
*4.
Only available for FX
Note:
If the forward rotation limit (LSF) and the reverse rotation limit (LSR) cannot be set, observe the following
items:
• Even if forward rotation limit 2 or reverse rotation limit 2 turns ON and the servo motor is automatically
stopped, the positioning instruction currently being activated cannot recognize the motor being stopped.
Therefore, pulses will be continuously output until the instruction is deactivated.
• The DOG search function of the DSZR instruction (zero return instruction with DOG search function)
cannot be used.
B - 46
Reverse rotation limit 1
(Programmable
controller side)
LSR
Reverse rotation
M8343
Forward limit relay for Y000
M8344
Reverse limit relay for Y000
Forward limit
Reverse limit
relay
relay
M8343
M8344
M8353
M8354
M8363
M8364
M8373
M8374
PLC.
3U
/FX
3U
and FX
3U
3UC
Forward rotation limit 1
(Programmable
controller side)
LSF
Forward rotation
Corresponding instruction and stop
PLSV instruction
*3
(M8338
=OFF)
If the corresponding rotation
limit relay is turned on,
pulse output (operation) will
immediately stop.
PLC Ver. 2.20 or later and FX
3UC
PLCs.
4 Before Programming
4.3 Various Special Relays for Operation Commands
Forward rotation limit 2
(Servo amplifier side)
DSZR, DVIT
*3
PLSV(M8338
and DRVA instructions
If the corresponding rotation
the
limit relay is turned on, the
speed will decelerate, and
operation will stop.
-2HSY-ADP adapters are
3U
PLC. If an FX
3G
3UC
*4
, ZRN,
=ON), DRVI,
the
PLC is
3G
PLC is used