6. EXECUTING THE COINCIDENCE OUTPUT FUNCTION

6.1.1 Coincidence output function operation

1) ...... Write a value in advance in 24-bit binary to the coincidence output point No. 1
setting area {addresses RWwm+3 to 4 (RWwm+B to C)}.
2) ...... When the counter value reaches the set coincidence output point value, the
counter value less signal switches off and the counter value coincidence signal
switches on.
3) ...... The coincidence signal reset command is switched on to reset the counter
value coincidence signal.
If the counter value coincidence signal remains on, the next coincident signal
cannot be issued.
4) ...... When the counter value becomes greater than the set coincidence signal
output point value, the counter value greater signal switches on.