PLC User's Manual - Positioning Control Edition
3G
3U
3UC
Built-in Positioning Functions
*1.
When the destination for pulse output on a FX
setting range is 10 to 100,000 Hz.
If an FX
be 10 to 200,000 Hz.
Set the creep speed so that the relation with the other speeds is "bias speed ≤ creep speed ≤
*2.
maximum speed."
*3.
The set interrupt input cannot be simultaneously used for a high-speed counter, input interruption,
pulse catch input, input for the SPD (FNC67) instruction, or for other interrupt inputs of the DVIT
(FNC151) instruction.
*4.
Note that this item can only be set if two FX
*5.
Only available for FX
*6.
Y002 is not available in 14-point and 24-point type FX
3. Click on the "Individual Setting" button to display the "Positioning instruction setting"
window. In this window, set the positioning table for each pulse output destination device.
Setting item
Y0
Y1
*1
Y2
*2
Y3
Rotation direction
signal
Head Address
No.
Positioning
Instruction
Pulse
Frequency (Hz)
"Up" button
"Down" button
B - 146
PLC is used, and if the pulse output destination is a FX
3U
and FX
3U
3UC
Click this tab to set the positioning table for Y000 (pulse output destination).
Click this tab to set the positioning table for Y001 (pulse output destination).
Click this tab to set the positioning table for Y002 (pulse output destination).
Click this tab to set the positioning table for Y003 (pulse output destination).
Set the rotation direction output number.
Initial setting:
Set the first device number to store the set data (number of pulses, frequency).
Starting from the set device, 1600 points
Table number
Data can be set for tables 1 to 100.
Select a positioning type from the following types:
DDVIT (Interrupt positioning)
DDRVI (Drive to Increment), DDRVA (Drive to Absolute)
Set the number of pulses to be output to perform the specified type of
positioning operation (instruction).
Set the speed (output pulse frequency) to perform the specified type of
positioning operation (instruction).
Click this button to move the cursor up by 1 line
(to select the line just above the cursor-positioned line).
Click this button to move the cursor down by 1 line
(to select the line just below the cursor-positioned line).
or FX
3U
3UC
-2HSY-ADP adapters are connected to the FX
3U
PLCs.
PLC.
3G
Description of setting
*3
Y010 for Y000 (pulse output destination)
Y011 for Y001 (pulse output destination)
Y012 for Y002 (pulse output destination)
*2
Y013 for Y003
(pulse output destination)
*4
will be occupied. Initial setting: R0
*5
, DPLSV (Variable Speed Pulse Output),
11 Batch Data Positioning Mode (TBL Instruction)
11.4 Positioning Parameter Setting
PLC is a built-in transistor output, the
-2HSY-ADP, the setting range will
3U
PLC.
3U
Setting range
-
-
-
-
*6
Y000 to Y357
M0 to M7679
S0 to S4095
D0 to D6400
*7
R0 to R31168
-
-
*8
-
-