Mitsubishi FX3G Series User Manual page 185

Melsec-f, positioning control edition, main unit/sink output/source output, line driver output
Hide thumbs Also See for FX3G Series:
Table of Contents

Advertisement

FX
/FX
/FX
PLC User's Manual - Positioning Control Edition
3G
3U
3UC
Built-in Positioning Functions
Setting item
"Insert" button
"Delete" button
"Delete All" button
Positioning table
setting will not be
initialized when the
PLC is powered on
"Write" button
"Read" button
*1.
Y002 is not available in 14-point and 24-point type FX
*2.
Note that this item can only be set if two FX
*3.
To use an FX
device as shown in the following table.
Pulse output destination device
*4.
1200 in the FX
*5.
Only available for FX
*6.
Up to Y000 to Y177 in the FX
*7.
Up to D0 to D6800, R0 to R22800 in the FX
*8.
Refer to the description of the selected instruction (positioning type).
DDVIT (Interrupt positioning)
DPLSV (Variable Speed Pulse Output)
DDRVI (Drive to Increment)
DDRVA (Drive to Absolute)
Description of setting
Click this button to insert a line at the specified position.
Click this button to delete the selected line.
Click this button to delete all the data from the positioning table of the selected
pulse output destination device.
If this check box is checked, the positioning data will not be initialized when the
PLC power is turned ON. Enter a check in this check box to retain the
changed data ("pulses" and "frequency" changed by the program, display
module, or HMI) even after power-off and to use the changed data after turning
on the power again. To use this function, set an uninterruptible power supply
type device as the first device.
Click this button to write 1600 points
the positioning table using GX Developer) starting from the first device of the
PLC.
Click this button to read out 1600 points
on the positioning table currently used) from the PLC starting from the first
device. At the completion of data reading, the data numbers will appear only if
"Positioning Instruction" is set for the data.
-2HSY-ADP, set the rotation direction signal depending on the pulse output destination
3U
Y000
Y001
Y002
Y003
series PLC.
3G
and FX
PLCs.
3U
3UC
series PLC.
3G
Positioning type
11 Batch Data Positioning Mode (TBL Instruction)
*4
of data ("pulses" and "frequency" set on
*4
of data ("pulses" and "frequency" set
PLC.
3G
-2HSY-ADP adapters are connected to the FX
3U
Rotation direction signal
Y004
Y005
Y006
Y007
series PLC.
3G
Refer to
Chapter 9
Chapter 10
Section 8.2
Section 8.3
11.4 Positioning Parameter Setting
Setting range
-
-
-
-
-
-
PLC.
3U
B - 147
A
B
Apx.