9.2
RS-485 / RS-232 Communication Parameters Setting
The following four parameters, P3-00 (Address Setting), P3-01 (Transmission Speed),
P3-02 (Communication Protocol) and P3-05 (Communication Mechanism), are essential
and must be set for the communication of the servo drive. The rest, such as P3-03
(Communication Error Disposal), P3-04 (Communication Timeout), P3-06 (Control Switch
of Digital Input), P3-07 (Communication Response Delay Time) and P3-08 (Monitor Mode)
is optional. Please refer to Chapter 8 of this user manual.
Parameter Abbr.
P3-00●
ADR Address Setting
P3-01
BRT Transmission Speed
P3-02
PTL Communication Protocol
P3-05
CMM Communication Mechanism
(★)
Read-only register, can only read the status. For example: parameter P0-00, P0-10
and P4-00, etc.
(▲)
Setting is unable when Servo On, e.g. parameter P1-00, P1-46 and P2-33, etc.
(●)
Not effective until re-power on or off the servo drive, e.g. parameter P1-01 and
P3-00.
(■)
Parameters of no data retained setting, e.g. parameter P2-30 and P3-06.
Revision December, 2014
Communication Parameter
Function
Chapter 9 Communication ASDA-A2R Series
Control Mode Related
Default Unit
PT PR S
0x7F
N/A
O O O O
bps
O O O O
0x0203
6
N/A
O O O O
0
N/A
O O O O
Section
T
7.3
7.3
7.3
7.3
9-3