P2-Xx Extension Parameters - Delta ASD-A2R-0221 Series User Manual

Asda-a2r series a high performance with diverse communication interfaces servo drive
Table of Contents

Advertisement

P2-xx Extension Parameters

P2-00
KPP
Operational
Interface:
Default: 35
Control
Mode:
Unit: rad/s
Range: 0 ~ 2047
Data Size: 16bit
Format: DEC
Settings: When the value of position loop gain is increased, the position
P2-01
PPR
Operational
Interface:
Default: 100
Control
Mode:
Unit: %
Range: 10 ~ 500
Data Size: 16bit
Format: DEC
Settings: Switch the changing rate of position loop gain according to the
P2-02
PFG
Operational
Interface:
Default: 50
Control
Mode:
Unit: %
Revision December, 2014
Position Loop Gain
Panel / Software
PT/PR
response can be enhanced and the position error can be
reduced. If the value is set too big, it may easily cause vibration
and noise.
Switching Rate of Position Loop Gain
Panel / Software
PT/PR
gain-switching condition.
Position Feed Forward Gain
Panel / Software
PT/PR
Chapter 8 ParametersASDA-A2R Series
Communication
Communication
Communication
Address: 0200H
0201H
Related Section:
6.2.8
Address: 0202H
0203H
Related Section:
6.2.8
Address: 0204H
0205H
Related Section:
6.2.8