Chapter 5 Operating
Restarting the TimeProvider 5000
Example
1. Type
show log event
Restarting the TimeProvider 5000
The system can be restarted via the
output signals will be lost, it is not recommended to restart the entire system unless
required. Only the admin user can issue the reboot command. The
command restarts the IMC card, and no output will be lost. If the system has two
IOC modules, each IOC can be rebooted separately to preserve the output.
Example:
1. Type
reboot imc
2. Type
reboot ioc1
3. Type
show status
4. After IOC1 has entered the standby state, type
applicable).
320 TimeProvider 5000 User's Guide
and press Enter.
reboot system
and press Enter.
and press Enter.
and press Enter to check the status of IOC1.
command. Since reference
reboot imc
and press Enter (if
reboot ioc2
098-00028-003 Revision A – June, 2011