Provisioning the Dedicated Outputs

Provisioning E1 Outputs
Port 3 and Port 4, the two dedicated output ports on the 090-50311-01 version of the
I/O module, must be provisioned for the type of output signal. The "set output
command is used to provision the dedicated E1 output characteristics. See
4-19.
Note:
from the factory; they cannot be reconfigured in the field.
Note: SSM is only supported for the frametypes ESF, CAS with
CRC4 and CCS with CRC4. SSM should not be enabled for other
output frame types
If the outputs are enabled and the telecom outputs are provisioned to
generate SSMs, the output SSM should be set to the LO's SSM
value, e.g. TYPE I (TNC) or TYPE III (ST3E).
2048kHz Frame Type
To provision the dedicated output Port 3 for a frametype of 2048kHz, CRC disabled,
SSM disabled, and to enable the port:
1. Login at the Admin or Config-user level.
2. Type
set output frametype port3 freq2048khz
3. Type
set output crc port3 disable
4. Type
set output ssm port3 disable
5. Type
set output state port3 enable
CCS Frame Type
To provision output Port 4 with a frametype of CCS, CRC enabled, SSM enabled,
SSM-bit of 6, and to enable the port:
1. Login at the Admin or Config-user level.
2. Type
set output frametype port4 ccs
3. Type
set output crc port4 enable
098-00028-003 Revision A – June, 2011
Units that provide dedicated E1 outputs must be ordered
Provisioning the Dedicated Outputs
and press Enter.
and press Enter.
and press Enter.
and press Enter.
and press Enter.
and press Enter.
TimeProvider 5000 User's Guide 279
Chapter 4 Provisioning
"
Figure