Chapter 3
TimeProvider 5000 CLI Command Set
show auto-sync
Displays the auto sync state
Command Syntax:
show auto-sync
Example:
tp5000> show auto-sync
Response:
AUTO-SYNC
Level :
User, Config, and Admin
set auto-sync
Provisions the auto sync IOC time to IMC time. This parameter is mainly used when
ToD-Source is set for GPS mode and the IOC has passed the warm-up state. When
auto sync is enabled, IOC time will be synchronized to IMC time if they are different.
If auto sync is disabled and IOC time is different from IMC time, an alarm will be
generated. The user can then use the
manually synchronize IOC time to IMC time.
Command Syntax:
set auto-sync {enable | disable}
Example:
tp5000> set auto-sync enable
Remarks: When the system is in warm-up state, IMC time and IOC time are always
synced automatically regardless of whether auto sync is enabled or not.
Level :
Config and Admin only
82
TimeProvider 5000 User's Guide
- enable
"Sync TOD-Source
now" command to
098-00028-003 Revision A – June, 2011