Symmetricom TimeProvider 5000 User Manual page 366

Ieee 1588 grand master clock / ntp server
Hide thumbs Also See for TimeProvider 5000:
Table of Contents

Advertisement

Appendix A System Messages
System Notification Messages
Table A-1. System Notification Messages (Continued)
Comp
Description
Input alarm
indication signal
Table A-2
(See
for
Secondary Index Info)
PTP server near
packet limit
Table A-2
(See
for
Secondary Index Info)
PTP server near
client limit
Table A-2
(See
for
Secondary Index Info)
PTP client is
unreachable
Table A-2
(See
for
Secondary Index Info)
Hardware-software
incompatible
IOC1
IOC2
EXPx
Table A-2
(See
for
x = 09
Secondary Index Info)
366 TimeProvider 5000 User's Guide
Event
MsgLevel
ID
ID
IOC
40
Minor
IOC
41
Minor
IOC
42
Minor
IOC
43
Event
IMC
44
Minor
Trans-
MsgText
itory
No
<input> alarm
indication signal
<input> alarm
indication signal
cleared
No
PTP server
exceeded <x%> of
packet limit on
<port>
PTP server near
packet limit cleared
on <port>
No
PTP server
exceeded <x%> of
client limit on <port>
PTP server near
client limit cleared
on <port>
No
PTP client <IP
address>
unreachable
PTP client <IP
address>
unreachable cleared
No
Hardware-software
incompatible
Hardware-software
incompatible cleared
098-00028-003 Revision A – June, 2011
Corrective Action
Check system input
reference
None required
Reduce number of
clients or client
request rate
None required
Increase number of
clients allowed or
reduce number of
clients total
None required
Check IP address
for correct
configuration,
possible network
problems. Check for
client down- if yes,
enable client
None required
Software upgrade
required
None required