Symmetricom TimeProvider 5000 User Manual page 76

Ieee 1588 grand master clock / ntp server
Hide thumbs Also See for TimeProvider 5000:
Table of Contents

Advertisement

Chapter 3
TimeProvider 5000 CLI Command Set
set alarm-config
Provisions the alarm state, alarm level, and reporting delay time for the specified
alarms.
Command Syntax:
To provision the state of the specified alarm number:
set alarm-config state {alarm [0 to max-alarm-id] | all}
{enable | disable}
To provision the Level of the specified Alarm number:
set alarm-config level {alarm [0 to max-alarm-id] | all}
{2 |3 | 4 | 5}
where:
To provision the reporting delay of the specified Alarm number in seconds:
set alarm-config delay {alarm [0 to max-alarm-id] | all}
[0 to 500000]
Note: Use "show alarm-config" command to view the max-alarm-id of
current TP5000 release.
Range:
Delay - 0 to 500,000 seconds
Default:
Delay - 0 seconds
Example 1:
To Disable alarm #35
tp5000> set alarm-config state alarm 35 disable
Example 2:
To set the level of alarm #31 to Error - major (3) 
tp5000> set alarm-config level alarm 31 3
76
TimeProvider 5000 User's Guide
2 - Critical
3 - Major
4 - Minor
5 - Event
098-00028-003 Revision A – June, 2011