Appendix C
Command
WX
WY
WZ
C-2
Command Descriptions
This section lists all ADFM commands. Each listing includes the com-
mand's purpose, format, range, and description. When appropriate, we in-
clude amplifying notes and examples. Most commands have a two-letter
identifier. The first letter identifies the command group (see Table C-26).
The second letter identifies the command function. If a numeric value fol-
lows the identifiers, the ADFM uses it to set a processing value (time,
range, percentage, processing flags). All measurement values are in metric
units (mm, cm, dm).
Table C-2:
First Letter
C
E
M
P
Q
R
T
V
W
page C-6
Default
Description
000
Mode 5 Depth (cm radial)
127
Mode 5 Correlation Threshold (0..255))
010
Mode 5 Ambiguity Velocity (cm/s radial)
ADFM Command Groups
Command Group
CONTROL Commands
ENVIRONMENTAL SENSORS Commands
MODEM Commands
PERFORMANCE Commands
DISCHARGE Commands
RECORDER Commands
TIMING Commands
VERTICAL BEAM Commands
WATER PROFILING Commands
MGD Technologies, Inc.