TS - Set Real-Time Clock

Purpose:
Format:
Range:
Description:
Example:
ADFM Technical Manual (January 2000)
Sets the ADFM's internal real-time clock
TSyymmddhhmmss
yy = 00-99 year
mm = 01-12 month
dd = 01-31 day
hh = 00-23 hour
mm = 0-59 minute
ss = 00-59 second
Sets the real time clock.
TS941123131500 sets the real-time clock to 1:15:00 pm, No-
vember 23, 1994.
When the ADFM receives the carriage return after the TS-
command, it enters the new time into the real-time clock and
sets hundredths of seconds to zero. The internal clock does ac-
count for leap years. If the entry is not valid, the ADFM sends
an error message and does not update the real-time clock.