Qp - Disc Params; Qr - Qvd Structure Only Rate; Qu - Channel Geometry Units - Teledyne ADFM Pro20 Technical Manual

Acoustic doppler flow meter
Hide thumbs Also See for ADFM Pro20:
Table of Contents

Advertisement

QP - Disc Params

Purpose:
Format:
Range:
Default:
Description:

QR - QVD Structure Only Rate

Purpose:
Format:
Range:
Default:
Description:
Example:

QU - Channel Geometry Units

Purpose:
Format:
Range:
Default:
Description:
ADFM Technical Manual (January 2000)
Sets the values used in the profiling algorithm and the power
law exponent used in the ModVA flow rate algorithm.
QPnnnn,nnnn
nnnn = Delta, N (0 = calculate, not 0 = fixed)
QP0500,0250
Contact MGD Technologies Inc. for further details.
Sets the rate at which full "PD0" zero ensembles are inter-
leaved between "PD3" ensembles.
QRnnn
nnn = 1 to 256 (1 = both always)
QR006
If PD3 is selected, a PD0 ensemble is output for ensemble #1
followed by several reduced discharge format ensembles.
When the ensemble is evenly divided by QR a full PD0 en-
semble is output.
PD = 3, QR = 4. Ensemble output order: FE, RD, RD, FE,
RD, RD, RD, FE, RD, RD, RD, FE, where FE = Full Ensem-
ble and RD is a reduced discharge output ensemble.
Sets the units the QH and QW (distances, not epsilons) are
entered in.
QUn
n = 0, 1 (0 = cm, 1 = mm)
QU0
Allows the ADFM to be set up using centimeters or millime-
ters for heights, widths, or radii.
ADFM Commands
page C-35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Adfm analog output moduleAdfm hot tap

Table of Contents