16.
POWER SUPPLY MODULE

16.1.3 Fuse specifications

This section describes the specifications of fuses used for the power supply modules and
output modules.
GTH4,
Item
FGTA250V 4A
or
FGTA250V 6A
SM250V 4A
Power supply
module
For A61P,
A61PN,
A61PEU,
Application
A62P,
A62PEU,
A65P,
A66P,
A67P
Type
Cartridge type
Cartridge type
Rated
4A
current
6 (0.2)
External
32 (1.2)
dimensions
mm (inch)
SM6.3A
MF51NM8
or
or
FGMA250V 8A
Power supply
Output module
module
For AY11E,
For A63P
AY13E
Cartridge type
6.3A
8A
6 (0.2)
5.2 (0.2)
32 (1.2)
20 (0.8)
mm (inch)
mm (inch)
Fuse specifications
Model Name
HP-32
HP-70K
Output module
Output module
For AY23
For AY22
Plug type
Plug type
3.2A
7A
30.3mm
30.3mm
(1.2inch)
(1.2inch)
8mm (0.3inch)
8mm (0.3inch)
20mm
20mm
(0.8inch)
(0.8inch)
16 - 7
MP-20
MP-32
Output module
Output module
For AY50, AY80
For AY60
Plug type
Plug type
2A
3.2A
17.2mm
17.2mm
(0.7inch)
(0.7inch)
5.5mm
5.5mm
(0.2inch)
(0.2inch)
19mm (0.7inch)
19mm (0.7inch)
MP-50
Output module
For AY60E
Plug type
5A
17.2mm
(0.7inch)
5.5mm
(0.2inch)
19mm (0.7inch)