Mitsubishi Q2ACPU User Manual page 496

Qna series melsec
Table of Contents

Advertisement

APPENDICES
Special
ACPU
Special
Register
Special
Register for
after
Register
Modification
Conversion
D9085
SD1085
D9090
SD1090
D9091
SD1091
D9094
SD1094
SD251
D9100
SD1100
D9101
SD1101
D9102
SD1102
D9103
SD1103
D9104
SD1104
D9105
SD1105
D9106
SD1106
D9107
SD1107
D9108
SD1108
D9109
SD1109
D9110
SD1110
D9111
SD1111
D9112
SD1112
D9113
SD1113
D9114
SD1114
D9116
SD1116
D9117
SD1117
D9118
SD1118
D9119
SD1119
D9120
SD1120
D9121
SD1121
D9122
SD1122
D9123
SD1123
Table App. 3.11. Special register
Name
Meaning
Register for
setting time
1 s to 65535 s
check value
Number of
Number of special
special
functions modules
functions
over
modules over
Detailed error
Self-diagnosis
code
detailed error code
Head I/O
Head I/O number of I/
number of I/O
O module to be
module to be
replaced
replaced
Bit pattern in units of
Fuse blown
16 points, indicating
module
the modules whose
fuses have blown
Step transfer
Timer setting valve
monitoring timer
and the F number at
setting
time out
Bit pattern, in units of
I/O module
16 points, indicating
verification error
the modules with
verification errors.
• Sets the time check time of the data link instructions (ZNRD,
ZNWR) for the MELSECNET/10.
• Setting range : 1 s to 65535 s (1 to 65535)
• Setting unit: 1 s
• Default value : 10 s (If 0 has been set, default 10 s is applied)
• For details, refer to the manual of each microcomputer program
package.
• Stores the detail code of cause of an instruction error.
• Stores the first two digits of the head I/O number of the I/O module,
which will be dismounted/mounted online (with power on), in BIN
value.
Example) Input module X2F0
• Output module numbers (in units of 16 points), of which fuses have
blown, are entered in bit pattern. (Preset output module numbers
when parameter setting has been performed.)
b15 b14b13b12b11b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
1
0
0
0
0
0
SD1100
(YC0)
0
0
0
0
0
0
SD1101
1
0
0
0
0
0
SD1107
Y7
B0
• Fuse blow check is executed also to the output module of remote I/
O station.
(If normal status is restored, clear is not performed. Therefore, it is
required to perform clear by user program.)
• Set the value of the step transition monitoring timer and the
annunciator number (F number) that will be turned ON when the
monitoring timer times out.
b15
to
b8
F number setting
(02 to 255)
• By turning ON any of SM1108 to SM1114, the monitoring timer
starts. If the transition condition following a step which corresponds
to the timer is not established within set time, set annunciator (F) is
turned on.)
• When I/O modules, of which data are different from those entered
at power-ON, have been detected, the I/O module numbers (in
units of 16 points) are entered in bit pattern. (Preset I/O module
numbers set in parmeters when parameter setting has been
performed.)
b15 b14b13b12b11b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
0
0
0
0
0
0
SD1116
0
0
0
0
0
0
SD1117
1
0
0
0
0
0
SD1123
XY
7B0
Indicates an I/O module verify error.
• I/O module verify check is executed also to remote I/O station
modules.
(If normal status is restored, clear is not performed. Therefore, it is
required to perform clear by user program.)
App - 99
Details
H2F
1
0
0
0
0
0
0
0
0
0
(Y80)
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
Y7
30
Indicates fuse blow.
b7
to
b0
Timer time limit setting
(1 to 255 s:(1 s units))
1
0
0
0
0
0
0
0
0
0
XY
0
1
0
0
0
0
0
0
0
0
0
XY
190
0
0
0
0
0
0
0
0
0
0
Corresponding
CPU
QnA
QnA
QnA
QnA
QnA
QnA
QnA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q3acpuQ4acpuQ2acpus1

Table of Contents