APPENDICES
(2) System information
Number
Name
SM202
LED OFF command
SM203
STOP contact
SM204
PAUSE contact
SM205
STEP-RUN contact
SM206
PAUSE enable coil
SM210
Clock data set request
SM211
Clock data error
SM212
Clock data display
Clock data read
SM213
request
SM250
Max. loaded I/O read
SM251
I/O change flag
SM252
I/O change OK
SM255
MELSECNET/10
SM256
module 1 information
SM257
SM260
MELSECNET/10
SM261
module 2 information
SM262
SM265
MELSECNET/10
SM266
module 3 information
SM267
SM270
MELSECNET/10
SM271
module 4 information
SM272
SM280
CC-Link error
Table App. 2.3. Special relay
Meaning
• When this relay goes from OFF to ON, the LEDs
OFF
ON : LED OFF
corresponding to the individual bits at SD202 go off
STOP status
• Goes ON at STOP status
PAUSE status
• Goes ON at PAUSE status
STEP-RUN status
• Goes ON at STEP-RUN status
OFF : PAUSE disabled
• PAUSE status is entered if this relay is ON when the
ON
: PAUSE enabled
PAUSE contact goes ON
• When this relay goes from OFF to ON and after END
OFF : Ignored
instruction execution of subsequent scan, clock data
ON
: Set request
stored in SD210 to SD213 are written to the CPU
module.
OFF : No error
• ON when error is generated in clock data (SD210 to
ON
: Error
SD213) value, and OFF if no error is detected.
• Displays clock data as month, day, hour, minute, and
OFF : Ignored
second at the LED display at front of CPU
ON
: Display
module.(Enabled only for Q3ACPU and Q4ACPU)
OFF : Ignored
• When this relay is ON, clock data is read to SD210 to
ON
: Read request
SD213 as BCD values.
OFF : Ignored
• When this relay goes from OFF to ON, maximum
ON
: Read
loaded I/O number is read to SD250.
• By turning this relay ON after setting the head I/O
number of the replaced I/O module to SD251, the I/O
module can be replaced online (with power on).
(Only one module can be replaced for each setting.)
OFF : No replacement
• Turn this relay ON in the test mode of the program or
ON
: Replacement
peripheral device for an I/O module change during
RUN, or in the test mode of the peripheral device for
an I/O change during STOP.
• Do not execute a RUN/STOP mode change until I/O
module change is finished.
OFF : Replacement
prohibited
• Goes ON when I/O replacement is OK.
ON
: Replacement enabled
• Goes ON for standby network(If no designation has
OFF : Operative network
been made concerning active or standby, active is
ON
: Standby network
assumed.)
OFF : Reads
• For refresh from link to CPU module (B, W, etc.)
ON
: Does not read
indicate whether to read from the link module.
OFF : Writes
• For refresh from CPU module to link (B, W, etc.),
ON
: Does not write
designate whether to write to the link module.
• Goes ON for standby network
OFF : Operative network
(If no designation has been made concerning active
ON
: Standby network
or standby, active is assumed.)
OFF : Reads
• For refresh from link to CPU module (B, W, etc.)
ON
: Does not read
indicate whether to read from the link module.
OFF : Writes
• For refresh from CPU module to link (B, W, etc.),
ON
: Does not write
designate whether to write to the link module.
• Goes ON for standby network
OFF : Operative network
(If no designation has been made concerning active
ON
: Standby network
or standby, active is assumed.)
OFF : Reads
• For refresh from link to CPU module (B, W, etc.)
ON
: Does not read
indicate whether to read from the link module.
OFF : Writes
• For refresh from CPU module to link (B, W, etc.),
ON
: Does not write
designate whether to write to the link module.
• Goes ON for standby network
OFF : Operative network
(If no designation has been made concerning active
ON
: Standby network
or standby, active is assumed.)
OFF : Reads
• For refresh from link to CPU module (B, W, etc.)
ON
: Does not read
indicate whether to read from the link module.
OFF : Writes
• For refresh from CPU module to link (B, W, etc.),
ON
: Does not write
designate whether to write to the link module.
• Goes ON when a CC-Link error is detected in any of
OFF : Normal
the installed CC-Link module. Remains ON if the
ON
: Error
condition is restored to normal thereafter.
Explanation
App - 51
Corres-
Set by
ponding
Corresponding
ACPU
(When Set)
M9
U
New
S (Status change)
M9042
S (Status change)
M9041
S (Status change)
M9054
U
M9040
U
M9025
S (Request)
M9026
U
M9027
U
M9028
U
New
U
M9094
S (END)
New
S (Initial)
New
U
New
U
New
S (Initial)
New
U
New
U
New
S (Initial)
New
U
New
U
New
S (Initial)
New
U
New
U
New
S (Error)
New
CPU
QnA
QnA
QnA
QnA
QnA
QnA
QnA
Q3A
Q4A
Q4AR
QnA
QnA
Q2A(S1)
Q3A
Q4A
Q4AR
QnA
QnA
QnA
QnA
QnA