Mitsubishi Q2ACPU User Manual page 457

Qna series melsec
Table of Contents

Advertisement

APPENDICES
ACPU
Special
Special
Special
Relay after
Relay for
Relay
Conversion
Modification
M9011
SM1011
SM56
M9012
SM1012
SM700
M9016
SM1016
M9017
SM1017
M9020
SM1020
M9021
SM1021
M9022
SM1022
M9023
SM1023
M9024
SM1024
M9025
SM1025
M9026
SM1026
M9027
SM1027
M9028
SM1028
M9029
SM1029
M9030
SM1030
M9031
SM1031
M9032
SM1032
M9033
SM1033
M9034
SM1034
M9036
SM1036
M9037
SM1037
M9038
SM1038
M9039
SM1039
Table App. 2.10. Special relay
Name
Operation error
OFF : No error
flag
ON
OFF : Carry OFF
Carry flag
ON
Data memory clear
OFF : lgnored
flag
ON
Data memory clear
OFF : lgnored
flag
ON
User timing clock
No.0
User timing clock
No.1
n2 scan
User timing clock
No.2
User timing clock
No.3
User timing clock
No.4
OFF : Ignored
Clock data set
ON
request
OFF : No error
Clock data error
ON
OFF : Ignored
Clock data display
ON
Clock data read
OFF : Ignored
request
ON
Batch processing
OFF : Batch processing not
of data
communications
ON
requests
0.05s
0.1 second clock
0.1s
0.2 second clock
0.5s
1 second clock
1s
2 second clock
2n minute clock(1
ns
minute clock)*
ON
Always ON
OFF
ON
Always OFF
OFF
ON for 1 scan only
ON
after RUN
OFF
RUN flag(After
ON
RUN, OFF for 1
OFF
scan only)
Meaning
• Turned on when operation error occurs during execution
of application instruction.
: Error
• Remains ON if the condition is restored to normal
thereafter.
• Carry flag used in application instruction.
: Carry ON
• Clears the data memory including the latch range (other
than special relays and special registers) in remote run
: Output claered
mode from computer, etc. when SM1016 is on.
• Clears the unlatched data memory (other than special
relays and special egisters) in remote run mode from
: Output claered
computer, etc. when SM1017 is on.
• Relay which repeats on/off at intervals of predetermined
scan.
• When power is turned on or reset is per-formed, the clock
starts with off.
n2 scan
Set the intervals of on/off by DUTY instruction.
n1 scan
n1: ON scan interval
n2: OFF scan interval
• Writes the clock data stored in SD1025 to SD1028 to the
: Set request present
CPU module after the END instruction is executed in the
used
scan in which SM1025 turned from OFF to ON.
• Switched on by clock data (SD1025 to SD1028) error
: Error
• Clock data is read from SD1025 to SD1028 and month,
day, hour, minute and minute are indicated on the CPU
: Display
module front LED display.
• Reads clock data to SD1025 to SD1028 in BCD when
: Read request
SD1028 is on.
• The SM1029 relay is turned on using a sequence program
to process all data communication requests accepted
during one scan in the END processing of that scan.
conducted
• The batch processing of the data communication requests
: Batch processing
can be turned on and off during running.
conducted
• The default is OFF (processed one at a time for each END
processing in the order in which data communication
requests are accepted).
0.05s
• 0.1 second, 0.2 second, 1 second and 2 second, clocks
are generated.
0.1s
• Not turned on or off per scan but turned on and off even
during scan if corresponding time has elapsed.
• Starts with off when PLC power supply is turned on or
0.5s
CPU module reset is performed.
1s
• Alternates between ON and OFF according to the
seconds specified at SD414. (Default: n = 30)
• Not turned on or off per scan but turned on and off even
ns
during scan if corresponding time has elapsed.
• Starts with off when PLC power supply is turned on or
CPU module reset is performed..
• Used as dummy contacts of initialization and application
instruction in sequence program.
• SM1038 and SM1037 are turned on and off without regard
to position of key switch on CPU module front. SM1038
and SM1039 are under the same condition as RUN status
except when the key switch is at STOP position, and
turned off and on. Switched off if the key switch is in STOP
1 scan
position. SM1038 is on for one scan only and SM1039 is
off for one scan only if the key switch is not in STOP
position.
1 scan
App - 60
Details
DUTY n1 n2 SM1020
Corresponding
CPU
QnA
QnA
QnA
QnA
QnA
QnA
QnA
QnA
QnA
Q3A
Q4A
Q4AR
QnA
QnA
QnA
QnA