SRX240 Services Gateway Hardware Guide
Related
Documentation
SRX240 Services Gateway DC Power Specifications and Requirements
DC Power System Electrical Specifications
DC Power Cable Specifications
38
Table 20: AC Power Cord Specifications (continued)
Country
United Kingdom
WARNING:
The AC power cord for the services gateway is intended for use
with the services gateway only and not for any other use.
SRX240 Services Gateway Site Electrical Wiring Guidelines on page 35
SRX240 Services Gateway Grounding Specifications on page 59
SRX240 Services Gateway Power Supply on page 25
SRX240 Services Gateway DC Power Specifications and Requirements on page 38
This topic includes the following sections:
DC Power System Electrical Specifications on page 38
DC Power Cable Specifications on page 38
Table 21 on page 38
lists the DC power system electrical specifications.
Table 21: DC Power Supply Specifications for the SRX240 Services
Gateway
Power Requirement
DC input voltage
DC system current rating
Table 22 on page 38
summarizes the specifications for the power cables, which you must
supply.
Table 22: DC Power Supply Cable Specifications for the SRX240 Services
Gateway
Cable Type
Power
Model Number
CBL-JX-PWR-UK
Specification
Operating range: –40.5 to –72 VDC
5A @ -48 VDC
Specification
Four 12-14 AWG (3.31 to 2.08 mm2), minimum 60°C wire, or as
permitted by the local code.