Alcatel-Lucent 5620 Troubleshooting Manual page 95

Service aware manager release 8.0
Hide thumbs Also See for 5620:
Table of Contents

Advertisement

Alarm
Name: IPSecTunnelBfdConnectionDown
Type: serviceAlarm (16)
Probable cause: bfdSessionDown (346)
Name:
IPSecTunnelBfdConnectionPeerDetectsDow
n
Type: serviceAlarm (16)
Probable cause:
bfdSessionConnectionPeerDetectsDown
(594)
Name: IPSecTunnelDown
Type: serviceAlarm (16)
Probable cause: tunnelDown (23)
(2 of 2)
Alarm
Name: IsaAaGrpCapCostThres
Type: equipmentAlarm (3)
Probable cause: IsaAaGrpCapCostThres
(595)
Name: IsaAaGrpDown
Type: equipmentAlarm (3)
Probable cause: IsaAaGrpDown (482)
Name: IsaAaGrpFailure
Type: equipmentAlarm (3)
Probable cause: isaAaGrpFailure (434)
Name: IsaAaGrpFlowFull
Type: equipmentAlarm (3)
Probable cause: isaAaGrpFlowFull (436)
Name: IsaAaGrpNonRedundant
Type: equipmentAlarm (3)
Probable cause: isaAaGrpNonRedundant
(435)
Name: IsaAaGrpSwitchover
Type: equipmentAlarm (3)
Probable cause: isaAaGrpSwitchover (437)
(1 of 2)
Alcatel-Lucent 5620 Service Aware Manager, Release
3HE 05723
AAAD
TQZZA Edition 01
Attributes
Severity: Minor
Object Type (class): IPSecTunnelBfd
Domain: ipsec
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): IPSecTunnelBfd
Domain: ipsec
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): IPSecTunnel
Domain: ipsec
Implicitly cleared (self-clearing): Yes
Table 3-25 Domain: isa
Attributes
Severity: Warning
Object Type (class): AaGroupMember
Domain: isa
Implicitly cleared (self-clearing): No
Severity: Major
Object Type (class): AaGroup
Domain: isa
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): AaGroup
Domain: isa
Implicitly cleared (self-clearing): No
Severity: Warning
Object Type (class): AaGroup
Domain: isa
Implicitly cleared (self-clearing): No
Severity: Warning
Object Type (class): AaGroup
Domain: isa
Implicitly cleared (self-clearing): No
Severity: Warning
Object Type (class): AaGroup
Domain: isa
Implicitly cleared (self-clearing): No
8.0 R4
Aug 2010
Troubleshooting Guide
3 — Troubleshooting using network alarms
Additional information
The alarm is raised when the
Operational State of a BFD session is
Not Connected.
The alarm is raised when a BFD peer
detects a connection timeout.
The alarm is raised when the IPsec
tunnel Operational State changes to
Down and the Administrative State is
Up.
Additional information
The alarm is raised when the
capacity cost for an MDA in an ISA-AA
group reaches the configured
threshold.
The alarm is raised when an ISA-AA
group Operational State is Down, and
the Administrative State is Up.
The alarm is raised when an ISA-AA
Group has no configured primary
MDA or the number of active MDAs is
not equal to the number of
configured primary MDAs.
The alarm is raised when an ISA-AA
group uses a greater number of flow
records than the value specified by
tmnxBsxFlowFullHighWatermark.
The alarm is raised when an ISA-AA
Group has a configured backup MDA
but there is no standby MDA
available.
The alarm is raised when an ISA-AA
group experiences an activity switch
from one ISA-AA to another.
3-53

Advertisement

Table of Contents
loading