Alcatel-Lucent 5620 Troubleshooting Manual page 79

Service aware manager release 8.0
Hide thumbs Also See for 5620:
Table of Contents

Advertisement

Alarm
Name: DDMRxOpticalPowerHighAlarm
Type: thresholdAlarm (49)
Probable cause: rxOpticalPowerHighAlarm
(377)
Name: DDMRxOpticalPowerHighWarning
Type: thresholdAlarm (49)
Probable cause:
rxOpticalPowerHighWarning (376)
Name: DDMRxOpticalPowerLowAlarm
Type: thresholdAlarm (49)
Probable cause: rxOpticalPowerLowAlarm
(375)
Name: DDMRxOpticalPowerLowWarning
Type: thresholdAlarm (49)
Probable cause: rxOpticalPowerLowWarning
(374)
Name: DDMSupplyVoltageHighAlarm
Type: thresholdAlarm (49)
Probable cause: supplyVoltageHighAlarm
(365)
Name: DDMSupplyVoltageHighWarning
Type: thresholdAlarm (49)
Probable cause: supplyVoltageHighWarning
(364)
Name: DDMSupplyVoltageLowAlarm
Type: thresholdAlarm (49)
Probable cause: supplyVoltageLowAlarm
(363)
Name: DDMSupplyVoltageLowWarning
Type: thresholdAlarm (49)
Probable cause: supplyVoltageLowWarning
(362)
Name: DDMTemperatureHighAlarm
Type: thresholdAlarm (49)
Probable cause: temperatureHighAlarm
(361)
(6 of 14)
Alcatel-Lucent 5620 Service Aware Manager, Release
3HE 05723
AAAD
TQZZA Edition 01
Attributes
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
8.0 R4
Aug 2010
Troubleshooting Guide
3 — Troubleshooting using network alarms
Additional information
The alarm is raised when the
received optical power of an SFP or
XFP reaches the maximum threshold
value.
The alarm is raised when the
received optical power of an SFP or
XFP approaches the maximum
threshold value.
The alarm is raised when the
received optical power of an SFP or
XFP reaches the minimum threshold
value.
The alarm is raised when the
received optical power of an SFP or
XFP approaches the minimum
threshold value.
The alarm is raised when the supply
voltage of an SFP or XFP reaches the
maximum threshold value.
The alarm is raised when the supply
voltage of an SFP or XFP approaches
the maximum threshold value.
The alarm is raised when the supply
voltage of an SFP or XFP reaches the
maximum threshold value.
The alarm is raised when the supply
voltage of an SFP or XFP approaches
the maximum threshold value.
The alarm is raised when the
temperature of an SFP or XFP
reaches the maximum threshold
value.
3-37

Advertisement

Table of Contents
loading

Table of Contents