Alarm
Name: AsymmetricalConfig
Type: configurationAlarm (11)
Probable cause: asymmetricalConfig (226)
Name: BundleDown
Type: equipmentAlarm (3)
Probable cause: bundleDown (128)
Name: IncompleteConfig
Type: configurationAlarm (11)
Probable cause: incompleteConfig (225)
Name: TrailSignalFail
Type: communicationsAlarm (4)
Probable cause: trailSignalFailure (565)
Alarm
Name: BWUtilizationExceeded
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Alarm
Name: CcagDown
Type: equipmentAlarm (3)
Probable cause: CcagDown (163)
Alcatel-Lucent 5620 Service Aware Manager, Release
3HE 05723
AAAD
TQZZA Edition 01
Table 3-7 Domain: bundle
Attributes
Severity: Major
Object Type (class):
MultiChassisApsInterface
Domain: bundle
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): Interface
Domain: bundle
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
MultiChassisApsInterface
Domain: bundle
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): Interface
Domain: bundle
Implicitly cleared (self-clearing): Yes
Table 3-8 Domain: cac
Attributes
Severity: Major
Object Type (class):
AbstractPhysicalLinkBandwidth
Domain: cac
Implicitly cleared (self-clearing): Yes
Table 3-9 Domain: ccag
Attributes
Severity: Major
Object Type (class):
CrossConnectAggregationGroup
Domain: ccag
Implicitly cleared (self-clearing): Yes
8.0 R4
Aug 2010
Troubleshooting Guide
3 — Troubleshooting using network alarms
Additional information
The alarm is raised when the bundles
in an APS group do not have matching
configurations.
The alarm is raised when the bundle
Administrative State is Up and the
Operational State is Down.
The alarm is raised when there are
not exactly two APS bundles in an
APS group.
The alarm is raised when a a local or
remote failure in an IMA group
generates a Trail Signal Fail
message.
Additional information
The alarm is raised when the per-CoS
or overall bandwidth utilization
exceeds the configured threshold.
Additional information
The alarm is raised when the CCAG
Administrative State is Up and the
Operational State is Down.