3 — Troubleshooting using network alarms
Alarm
Name: MissingRisingEvent
Type: configurationAlarm (11)
Probable cause: incompleteConfig (225)
(2 of 2)
Alarm
Name: RsvpDown
Type: ProtocolAlarm (1)
Probable cause: protocolDown (1)
Name: SessionDown
Type: ProtocolAlarm (1)
Probable cause: interfaceDown (32)
Alarm
Name: BfdSessionDown
Type: bfdSessionAlarm (46)
Probable cause: bfdSessionDown (346)
Name: BfdSessionMissing
Type: bfdSessionAlarm (46)
Probable cause: bfdSessionMissing (345)
Name: CpeUnreachable
Type: communicationsAlarm (4)
Probable cause: CpeUnreachable (334)
Name: SubscrAuthPolicyMisconfigured
Type: ConfigurationAlarm (15)
Probable cause: SubscrAuthPolicyNotFound
(203)
3-100
Attributes
Severity: Major
Object Type (class): Alarm
Domain: rmon
Implicitly cleared (self-clearing): No
Table 3-57 Domain: rsvp
Attributes
Severity: Critical
Object Type (class): Site
Domain: rsvp
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): Session
Domain: rsvp
Implicitly cleared (self-clearing): Yes
Table 3-58 Domain: rtr
Attributes
Severity: Warning
Object Type (class):
NetworkInterface
Domain: rtr
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class):
NetworkInterface
Domain: rtr
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): StaticRoute
Domain: rtr
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class):
VirtualInterfaceConfiguration
Domain: rtr
Implicitly cleared (self-clearing): Yes
Alcatel-Lucent 5620 Service Aware Manager, Release
Aug 2010
Troubleshooting Guide
Additional information
The alarm is raised when the
5620 SAM cannot find the rising
event object that is named in an
RMON policy alarm definition.
Additional information
The alarm is raised when an RSVP site
has an Operational State other than
Up, and the Administrative State is
Up.
The alarm is raised when an RSVP
session is operationally down.
Additional information
The alarm is raised when a BFD
session is operationally down.
The alarm is raised when a previously
present BFD session is absent.
The alarm is raised when the CPE
associated with a static route is
unreachable.
The alarm is raised when a subscriber
authentication policy for DHCP relay
is misconfigured.