Alarm
Name: WaveTrackerEncoderFailure
Type: communicationsAlarm (4)
Probable cause: EncoderFailure (585)
Name: WaveTrackerPowerControlDegrade
Type: communicationsAlarm (4)
Probable cause: PowerControlDegrade (586)
Name: WaveTrackerPowerControlFailure
Type: communicationsAlarm (4)
Probable cause: PowerControlFailure (587)
Name: WaveTrackerPowerControlHighlimit
Type: communicationsAlarm (4)
Probable cause: PowerControlHighlimit
(588)
Name: WaveTrackerPowerControllowlimit
Type: communicationsAlarm (4)
Probable cause: PowerControllowlimit (589)
(4 of 4)
Alarm
Name: RemoteMepCCMAlarm
Type: oamAlarm (18)
Probable cause: missingRemoteMep (388)
Alarm
Name: apsCfgRaiseAlarm
Type: configurationAlarm (11)
Probable cause: configurationMismatch
(548)
(1 of 2)
Alcatel-Lucent 5620 Service Aware Manager, Release
3HE 05723
AAAD
TQZZA Edition 01
Attributes
Severity: Major
Object Type (class):
WaveLengthTracker
Domain: ethernetequipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
WaveLengthTracker
Domain: ethernetequipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class):
WaveLengthTracker
Domain: ethernetequipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
WaveLengthTracker
Domain: ethernetequipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
WaveLengthTracker
Domain: ethernetequipment
Implicitly cleared (self-clearing): Yes
Table 3-16 Domain: ethernetoam
Attributes
Severity: Major
Object Type (class): Mep
Domain: ethernetoam
Implicitly cleared (self-clearing): Yes
Table 3-17 Domain: ethernettunnel
Attributes
Severity: Major
Object Type (class):
EthernetTunnelEndpoint
Domain: ethernettunnel
Implicitly cleared (self-clearing): Yes
8.0 R4
Troubleshooting Guide
3 — Troubleshooting using network alarms
Additional information
The alarm is raised when a device
reports an encoder failure on a
wavelength tracker interface.
The alarm is raised when a device
reports a power control degradation
on a wavelength tracker interface.
The alarm is raised when a device
reports a power control failure on a
wavelength tracker interface.
The alarm is raised when a device
reports a power control high limit on
a wavelength tracker interface.
The alarm is raised when a device
reports a power control low limit on
a wavelength tracker interface.
Additional information
The alarm is raised when a MEP loses
connectivity with one or more
remote MEPs. The Remote MEP DB
State tab on a MEP lists the missing
remote MEPs.
Additional information
The alarm is raised when the
5620 SAM detects a mismatch
between the working and protection
Ethernet tunnel group
configurations.