Alcatel-Lucent 5620 Troubleshooting Manual page 84

Service aware manager release 8.0
Hide thumbs Also See for 5620:
Table of Contents

Advertisement

3 — Troubleshooting using network alarms
Alarm
Name: LinkDown
Type: communicationsAlarm (4)
Probable cause: portLinkProblem (10)
Name: LossOfAlignment
Type: communicationsAlarm (4)
Probable cause: lossOfAlignment (468)
Name: LossOfFrame
Type: communicationsAlarm (4)
Probable cause: lossOfFrame (97)
Name: LossOfSignal
Type: communicationsAlarm (4)
Probable cause: lossOfSignal (99)
Name: MigrationCompleted
Type: migrationComplete (62)
Probable cause: migrationComplete (529)
Name: MigrationFailed
Type: migrationFailure (63)
Probable cause: migrationFailure (530)
Name: OutOfSlots
Type: configurationAlarm (11)
Probable cause: noAvailableSlotNumbers
(352)
Name: OverTemperatureDetected
Type: environmentalAlarm (2)
Probable cause: equipmentOverheated (5)
Name: PChipCAMEvent
Type: hardwareAnomaly (55)
Probable cause: camError (577)
Name: PChipError
Type: hardwareAnomaly (55)
Probable cause: pChipError (447)
(11 of 14)
3-42
Attributes
Severity: Major
Object Type (class): Equipment
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): Equipment
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Info
Object Type (class):
NeCardSwapTask
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Major
Object Type (class):
NeCardSwapTask
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Major
Object Type (class): Shelf
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Major
Object Type (class): Shelf
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): Card
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): BaseCard
Domain: equipment
Implicitly cleared (self-clearing): Yes
Alcatel-Lucent 5620 Service Aware Manager, Release
Aug 2010
Troubleshooting Guide
Additional information
The alarm is raised when a port has
no associated physical link.
The alarm is raised when a Loss of
Alignment signal is detected.
The alarm is raised when a port
receives a Loss Of Frame signal.
The alarm is raised when a Loss of
Signal signal is detected on a PDH
tributary.
The alarm is raised when a card
migration event completes.
The alarm is raised when a card
migration event fails.
The alarm is raised when a stack
element enters pass-through mode
because there is no slot number for
the element.
The alarm is raised when the chassis
temperature exceeds the maximum
threshold value.
The alarm is raised when an IOM or
CPM experiences a P-chip CAM error.
The alarm is raised when a P chip
reports persistent errors on the
specified complex in the specified
direction.
3HE 05723
AAAD
TQZZA Edition 01
8.0 R4

Advertisement

Table of Contents
loading