3 — Troubleshooting using network alarms
Alarm
Name: ResiliencySapDeleted
Type: resiliencyAlarm (58)
Probable cause: resiliencySapDeleted (503)
Name: ResiliencyServiceSwitch
Type: resiliencyAlarm (58)
Probable cause: secondaryServiceSiteActive
(504)
Name: ResiliencySiteDeleted
Type: resiliencyAlarm (58)
Probable cause:
secondaryServiceSiteDeleted (505)
Alarm
Name: HostConnectivityLostRateExceeded
Type: communicationsAlarm (4)
Probable causes:
hostDown (208)
trapDropped (209)
Name: NatL2AwSubIcmpPortUsageHigh
Type: equipmentAlarm (3)
Probable cause: resourceFull (53)
Name: NatL2AwSubSessionUsageHigh
Type: equipmentAlarm (3)
Probable cause: resourceFull (53)
Name: NatL2AwSubTcpPortUsageHigh
Type: equipmentAlarm (3)
Probable cause: resourceFull (53)
(1 of 2)
3-98
Table 3-53 Domain: resiliency
Attributes
Severity: Major
Object Type (class): HsdpaResiliency
Domain: resiliency
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): HsdpaResiliency
Domain: resiliency
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): HsdpaResiliency
Domain: resiliency
Implicitly cleared (self-clearing): Yes
Table 3-54 Domain: ressubscr
Attributes
Severity: Major
Object Type (class): ShcvSite
Domain: ressubscr
Implicitly cleared (self-clearing): No
Severity: Major
Object Type (class):
ResidentialSubscriberInstance
Domain: ressubscr
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
ResidentialSubscriberInstance
Domain: ressubscr
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
ResidentialSubscriberInstance
Domain: ressubscr
Implicitly cleared (self-clearing): Yes
Alcatel-Lucent 5620 Service Aware Manager, Release
Aug 2010
Troubleshooting Guide
Additional information
The alarm is raised when a SAP that
is used for resiliency is deleted.
The alarm is raised when a secondary
service becomes active.
The alarm is raised when a secondary
service site is deleted.
Additional information
The alarm is raised when the
trapDroppedRaisesAlarm parameter
is enabled and the maximum allowed
number of SHCV host connectivity
loss events on a SAP is exceeded. The
SHCV action in response to the alarm
is specified by the
maxHostLostConnectivityRate
parameter. If the specified action is
to remove the host information, the
host information is removed and the
connectivity of the host is not
subsequently verified.
The alarm is raised when the ICMP
port usage of an L2-aware NAT
subscriber reaches the high or low
watermark.
The alarm is raised when the session
usage of an L2-aware NAT subscriber
reaches the high or low watermark.
The alarm is raised when the TCP
port usage of an L2-aware NAT
subscriber reaches the high or low
watermark.
3HE 05723