Alcatel-Lucent 5620 Troubleshooting Manual page 80

Service aware manager release 8.0
Hide thumbs Also See for 5620:
Table of Contents

Advertisement

3 — Troubleshooting using network alarms
Alarm
Name: DDMTemperatureHighWarning
Type: thresholdAlarm (49)
Probable cause: temperatureHighWarning
(360)
Name: DDMTemperatureLowAlarm
Type: thresholdAlarm (49)
Probable cause: temperatureLowAlarm
(359)
Name: DDMTemperatureLowWarning
Type: thresholdAlarm (49)
Probable cause: temperatureLowWarning
(358)
Name: DDMTxBiasCurrentHighAlarm
Type: thresholdAlarm (49)
Probable cause: txBiasCurrentHighAlarm
(369)
Name: DDMTxBiasCurrentHighWarning
Type: thresholdAlarm (49)
Probable cause: txBiasCurrentHighWarning
(368)
Name: DDMTxBiasCurrentLowAlarm
Type: thresholdAlarm (49)
Probable cause: txBiasCurrentLowAlarm
(367)
Name: DDMTxBiasCurrentLowWarning
Type: thresholdAlarm (49)
Probable cause: txBiasCurrentLowWarning
(366)
Name: DDMTxOutputPowerHighAlarm
Type: thresholdAlarm (49)
Probable cause: txOutputPowerHighAlarm
(373)
Name: DDMTxOutputPowerHighWarning
Type: thresholdAlarm (49)
Probable cause:
txOutputPowerHighWarning (372)
(7 of 14)
3-38
Attributes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Alcatel-Lucent 5620 Service Aware Manager, Release
Aug 2010
Troubleshooting Guide
Additional information
The alarm is raised when the
temperature of an SFP or XFP
approaches the maximum threshold
value.
The alarm is raised when the
temperature of an SFP or XFP
reaches the maximum threshold
value.
The alarm is raised when the
temperature of an SFP or XFP
approaches the maximum threshold
value.
The alarm is raised when the
transmit bias current of an SFP or
XFP reaches the maximum threshold
value.
The alarm is raised when the
transmit bias current of an SFP or
XFP approaches the maximum
threshold value.
The alarm is raised when the
transmit bias current of an SFP or
XFP reaches the maximum threshold
value.
The alarm is raised when the
transmit bias current of an SFP or
XFP approaches the maximum
threshold value.
The alarm is raised when the output
power of an SFP or XFP reaches the
maximum threshold value.
The alarm is raised when the output
power of an SFP or XFP approaches
the maximum threshold value.
3HE 05723
AAAD
TQZZA Edition 01
8.0 R4

Advertisement

Table of Contents
loading