Alarm
Name: TunnelDown
Type: pathAlarm (12)
Probable cause: tunnelDown (23)
Name: TunnelOverbooked
Type: resourceAlarm (28)
Probable cause: tunnelOverbooked (442)
(3 of 3)
Alarm
Name: BootableConfigBackupFailed
Type: configurationAlarm (11)
Probable cause: fileTransferFailure (89)
Name: BootableConfigRestoreFailed
Type: configurationAlarm (11)
Probable cause: fileTransferFailure (89)
Name: BootEnvironmentSyncFailed
Type: equipmentAlarm (3)
Probable cause:
bootEnvironmentSyncFailed (87)
Name: certifyFailureAlarm
Type: softwareAlarm (19)
Probable cause: certifyFailureAlarm (402)
Name: ConfigFileSyncFailed
Type: equipmentAlarm (3)
Probable cause: configFileSyncFailed (88)
(1 of 3)
Alcatel-Lucent 5620 Service Aware Manager, Release
3HE 05723
AAAD
TQZZA Edition 01
Attributes
Severity: Critical
Object Type (class): Tunnel
Domain: svt
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): Tunnel
Domain: svt
Implicitly cleared (self-clearing): No
Table 3-73 Domain: sw
Attributes
Severity: Major
Object Type (class):
BackupRestoreManager
Domain: sw
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
BackupRestoreManager
Domain: sw
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class):
SoftwareUpgradeManager
Domain: sw
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
SoftwareControlModule
Domain: sw
Implicitly cleared (self-clearing): No
Severity: Critical
Object Type (class):
SoftwareUpgradeManager
Domain: sw
Implicitly cleared (self-clearing): Yes
8.0 R4
Aug 2010
Troubleshooting Guide
3 — Troubleshooting using network alarms
Additional information
The alarm is raised when the
5620 SAM detects that a service
tunnel is operationally down.
The alarm is raised when the
allocated SDP binding bandwidth
specified by sdpBookedBandwidth
exceeds the
sdpMaxBookableBandwidth value.
Additional information
The alarm is raised when the
5620 SAM fails to back up a set of NE
configuration files.
The alarm is raised when the
5620 SAM fails to restore a set of NE
configuration files.
The alarm is raised when the
synchronization of one or more
system initialization files between
the active and standby CPM cards
fails. See the 7750 SR OS System
Guide for more information.
The alarm is raised when the
software certification process on an
NE fails.
The alarm is raised when the
configuration file synchronization
between the active and standby CPM
cards fails.
3-123