Alcatel-Lucent 5620 Troubleshooting Manual page 139

Service aware manager release 8.0
Hide thumbs Also See for 5620:
Table of Contents

Advertisement

Alarm
Name: IncompatiblePTX
Type: communicationsAlarm (4)
Probable cause: incompatiblePTX (499)
Name: IncompatibleShifter
Type: communicationsAlarm (4)
Probable cause: incompatibleShifter (500)
Name: LinkIdentifierMismatch
Type: communicationsAlarm (4)
Probable cause: linkIdentifierMismatch
(501)
Name: LoopProblem
Type: communicationsAlarm (4)
Probable cause: loopProblem (851)
Name: RPSFail
Type: communicationsAlarm (4)
Probable cause: receiverProtectionFail
(824)
Name: RxFail
Type: communicationsAlarm (4)
Probable cause: rxFail (502)
(2 of 2)
Alarm
Name: RadisuAcctPlcyFailure
Type: radiusAccountingPolicyAlarm (38)
Probable cause:
radiusAccountingRequestFailure (260)
Alcatel-Lucent 5620 Service Aware Manager, Release
3HE 05723
AAAD
TQZZA Edition 01
Attributes
Severity: Major
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
RadioPortSpecifics
Domain: radioequipment
Implicitly cleared (self-clearing): Yes
Table 3-52 Domain: radiusaccounting
Attributes
Severity: Major
Object Type (class): Policy
Domain: radiusaccounting
Implicitly cleared (self-clearing): No
8.0 R4
Troubleshooting Guide
3 — Troubleshooting using network alarms
Additional information
The alarm is raised when the
provisioned MSS transmit power is
incompatible with the MSS hardware.
The alarm is raised when the
provisioned MSS shifter parameters
are incompatible with the MSS
hardware.
The alarm is raised when an MSS
detects a link identifier mismatch.
The alarm is raised when a receiver
protection switchover fails.
The alarm is raised when a receiver
protection switchover fails.
The alarm is raised when an MSS
detects a receive failure.
Additional information
The alarm is raised when a RADIUS
accounting request is not
successfully sent to any of the
RADIUS servers specified in the
RADIUS accounting policy.
Aug 2010
3-97