Alcatel-Lucent 5620 Troubleshooting Manual page 87

Service aware manager release 8.0
Hide thumbs Also See for 5620:
Table of Contents

Advertisement

Alarm
Name: SychronizationLossOfSignal
Type: communicationsAlarm (4)
Probable cause: lossOfSignal (99)
Name: TemperatureThresholdCrossed
Type: environmentalAlarm (2)
Probable cause: equipmentOverheated (5)
Name: TemporaryCommunicationFailure
Type: equipmentAlarm (3)
Probable cause:
temporaryCommunicationProblem (566)
Name: ThresholdCrossingAlarm
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Name: UnavailableTime
Type: communicationsAlarm (4)
Probable cause: unavailableTime (480)
Name: UnconfiguredEquipmentPresent
Type: equipmentAlarm (3)
Probable cause:
unconfiguredEquipmentPresent (481)
Name: upgradedCardAlarm
Type: softwareAlarm (19)
Probable cause: upgradedCard (194)
Name: VersionMismatch
Type: equipmentAlarm (3)
Probable cause: versionMismatch (405)
Name: XplError
Type: hardwareAnomaly (55)
Probable cause: xplError (443)
(14 of 14)
Alcatel-Lucent 5620 Service Aware Manager, Release
3HE 05723
AAAD
TQZZA Edition 01
Attributes
Severity: Major
Object Type (class): Shelf
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): Environment
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): Equipment
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): Equipment
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): Card
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): Equipment
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): DaughterCard
Domain: equipment
Implicitly cleared (self-clearing): Yes
8.0 R4
Aug 2010
Troubleshooting Guide
3 — Troubleshooting using network alarms
Additional information
The alarm is raised when an SLOS
signal is detected on a PDH tributary.
The alarm is raised when a
temperature crosses a threshold.
The alarm is raised when a
temporary communication failure is
detected.
The alarm is raised when a port value
crosses a threshold.
The alarm is raised when a port
experiences 10 consecutive SES.
The alarm is raised when
unconfigured equipment is detected.
The alarm is raised when the standby
CPM is rebooted and operational
after a software upgrade. A device
resets an IOM automatically after 120
minutes if the IOM is not manually
reset after a CPM upgrade.
The alarm is raised when an ODU
software version mismatch is
detected.
The alarm is raised when an MDA
reports persistent XPL Errors.
3-45