3 — Troubleshooting using network alarms
Alarm
Name: SecondaryPathLimitReached
Type: resourceAlarm (28)
Probable cause: resourceLimitReached
(131)
Name: SGLimitExceeded
Type: resourceAlarm (28)
Probable cause:
pimSnpgSGGroupMaxSupportedLimitExceed
ed (350)
Name: ShelfCPUAboveThreshold
Type: configurationAlarm (11)
Probable cause:
ShelfCPUUtilizationCrossedAboveThreshold
(474)
Name: ShelfMemoryAboveThreshold
Type: configurationAlarm (11)
Probable cause:
ShelfMemoryUtilizationCrossedAboveThresh
old (475)
Name: ShelfRxAboveThreshold
Type: configurationAlarm (11)
Probable cause:
ShelfRxUtilizationCrossedAboveThreshold
(476)
Name: ShelfRxTxAboveThreshold
Type: configurationAlarm (11)
Probable cause:
ShelfRxTxUtilizationCrossedAboveThreshold
(477)
Name: ShelfTemperatureAboveThreshold
Type: configurationAlarm (11)
Probable cause:
ShelfTemperatureUtilizationCrossedAboveT
hreshold (478)
Name: SoftwareFailureAlarm
Type: softwareAlarm (19)
Probable cause: loadFailed (124)
Name: SSHServerPreserveKeyFailure
Type: softwareAlarm (19)
Probable cause: preserveKeyFailure (302)
Name: SWIncompatibility
Type: configurationAlarm (11)
Probable cause:
elementNotCompatibleWithExistingStack
(357)
(13 of 14)
3-44
Attributes
Severity: Warning
Object Type (class): DaughterCard
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): Card
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Major
Object Type (class):
HealthMonitoring
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Major
Object Type (class):
HealthMonitoring
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Major
Object Type (class):
HealthMonitoring
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Major
Object Type (class):
HealthMonitoring
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Major
Object Type (class):
HealthMonitoring
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Critical
Object Type (class): ReplaceableUnit
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): FlashMemory
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Major
Object Type (class):
StackConfiguration
Domain: equipment
Implicitly cleared (self-clearing): No
Alcatel-Lucent 5620 Service Aware Manager, Release
Aug 2010
Troubleshooting Guide
Additional information
The alarm is raised when the
secondary path bandwidth limit is
reached.
The alarm is raised when the number
of PIM snooping source group records
on a card exceeds the maximum.
The alarm is raised when shelf CPU
usage exceeds the threshold value.
The alarm is raised when shelf
memory usage exceeds the threshold
value.
The alarm is raised when shelf Rx
exceeds the threshold value.
The alarm is raised when shelf Tx
exceeds the threshold value.
The alarm is raised when shelf
temperature exceeds the threshold
value.
The alarm is raised when the CPM
fails to load the software from the
specified location. The alarm
information includes the software
location.
The alarm is raised when the CPM
fails to save the SSH server host key
on the persistent drive.
The alarm is raised when a slot is not
compatible with the current stack.
The slot subsequently enters
pass-through mode.
3HE 05723
AAAD
TQZZA Edition 01
8.0 R4