Alarm
Name: SubnetMismatch
Type: configurationAlarm (11)
Probable cause: ipAddressListMismatch
(308)
(2 of 2)
Alarm
Name: backupScriptInUse
Type: configurationAlarm (11)
Probable cause: backupInUse (206)
Name: noFunctioningScript
Type: configurationAlarm (11)
Probable cause: primaryBackupDown (207)
Name: scriptBackupLost
Type: configurationAlarm (11)
Probable cause: backupDown (205)
Alarm
Name: TodSuiteAssignmentFailure
Type: todSuiteAlarm (35)
Probable cause: assignmentFailure (242)
Alarm
Name: FrameSizeProblem
Type: configurationAlarm (11)
Probable cause: frameSizeProblem (33)
(1 of 3)
Alcatel-Lucent 5620 Service Aware Manager, Release
3HE 05723
AAAD
TQZZA Edition 01
Attributes
Severity: Major
Object Type (class): Instance
Domain: srrp
Implicitly cleared (self-clearing): Yes
Table 3-70 Domain: subscrident
Attributes
Severity: Major
Object Type (class): Policy
Domain: subscrident
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): Policy
Domain: subscrident
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): Policy
Domain: subscrident
Implicitly cleared (self-clearing): Yes
Table 3-71 Domain: svq
Attributes
Severity: Minor
Object Type (class):
AggregationScheduler
Domain: svq
Implicitly cleared (self-clearing): No
Table 3-72 Domain: svt
Attributes
Severity: Critical
Object Type (class): SdpBinding
Domain: svt
Implicitly cleared (self-clearing): Yes
8.0 R4
Aug 2010
Troubleshooting Guide
3 — Troubleshooting using network alarms
Additional information
The alarm is raised when the IP
address list received from the master
does not match the local IP address
list.
Additional information
The alarm is raised when the primary
subscriber identification script is
operationally down, but one of the
other scripts is operationally up.
The alarm is raised when all
subscriber identification scripts are
operationally down.
The alarm is raised when the primary
subscriber identification script URL is
operationally up, but a
lower-priority script or URL is
operationally down.
Additional information
The alarm is raised when an object
fails to perform the action specified
in a Time of Day suite.
Additional information
The alarm is raised when a
provisioned MTU size value is greater
than the supported MTU size value.
3-121