Alcatel-Lucent 5620 Troubleshooting Manual page 78

Service aware manager release 8.0
Hide thumbs Also See for 5620:
Table of Contents

Advertisement

3 — Troubleshooting using network alarms
Alarm
Name: DaughterCardConfigNotCompatible
Type: equipmentAlarm (3)
Probable cause:
DaughterCardConfigNotCompatible (301)
Name: DDMAux1HighAlarm
Type: thresholdAlarm (49)
Probable cause: aux1HighAlarm (381)
Name: DDMAux1HighWarning
Type: thresholdAlarm (49)
Probable cause: aux1HighWarning (380)
Name: DDMAux1LowAlarm
Type: thresholdAlarm (49)
Probable cause: aux1LowAlarm (379)
Name: DDMAux1LowWarning
Type: thresholdAlarm (49)
Probable cause: aux1LowWarning (378)
Name: DDMAux2HighAlarm
Type: thresholdAlarm (49)
Probable cause: aux2HighAlarm (385)
Name: DDMAux2HighWarning
Type: thresholdAlarm (49)
Probable cause: aux2HighWarning (384)
Name: DDMAux2LowAlarm
Type: thresholdAlarm (49)
Probable cause: aux2LowAlarm (383)
Name: DDMAux2LowWarning
Type: communicatiothresholdAlarmnsAlarm
(50)
Probable cause: aux2LowWarning (382)
(5 of 14)
3-36
Attributes
Severity: Critical
Object Type (class):
DaughterCardSlot
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class):
DigitalDiagnosticMonitoring
Domain: equipment
Implicitly cleared (self-clearing): Yes
Alcatel-Lucent 5620 Service Aware Manager, Release
Aug 2010
Troubleshooting Guide
Additional information
The alarm is raised when a supported
MDA is inserted into a compatible
IOM slot, but the configuration on
the MDA ports is not compatible with
the MDA.
The alarm is raised when the
manufacturer-specific Auxiliary 1 of
the XFP reaches the maximum
threshold value.
The alarm is raised when the
manufacturer-specific Auxiliary 1 of
the XFP approaches the maximum
threshold value.
The alarm is raised when the
manufacturer-specific Auxiliary 1 of
the XFP reaches the minimum
threshold value.
The alarm is raised when the
manufacturer-specific Auxiliary 1 of
the XFP approaches the minimum
threshold value.
The alarm is raised when the
manufacturer-specific Auxiliary 2 of
the XFP reaches the maximum
threshold value.
The alarm is raised when the
manufacturer-specific Auxiliary 2 of
the XFP approaches the maximum
threshold value.
The alarm is raised when the
manufacturer-specific Auxiliary 2 of
the XFP reaches the minimum
threshold value.
The alarm is raised when the
manufacturer-specific Auxiliary 2 of
the XFP approaches the minimum
threshold value.
3HE 05723
AAAD
TQZZA Edition 01
8.0 R4

Advertisement

Table of Contents
loading

Table of Contents