Alcatel-Lucent 5620 Troubleshooting Manual page 83

Service aware manager release 8.0
Hide thumbs Also See for 5620:
Table of Contents

Advertisement

Alarm
Name: FanFailure
Type: equipmentAlarm (3)
Probable cause: fanFailure (116)
Name: FanTrayRemoved
Type: equipmentAlarm (3)
Probable cause: FanTrayRemoved (438)
Name: FIBHighOccupancy
Type: resourceAlarm (28)
Probable cause: FIBHighOccupancy (528)
Name: FibOutOfSynch
Type: resourceAlarm (28)
Probable cause: fibUpdateFailed (464)
Name: FirmwareDownloadOnGoing
Type: equipmentAlarm (3)
Probable cause: firmwareDownloadOnGoing
(465)
Name: FirmwareMismatchAlarm
Type: firmwareAlarm (26)
Probable causes:
bootRomVersionMismatch (119)
fpgaVersionMismatch (120)
Name: FirmwareUpgradeAlarm
Type: firmwareAlarm (26)
Probable cause: firmwareUpgraded (169)
Name: HardwareRedundancyAlarm
Type: equipmentAlarm (3)
Probable cause: primaryCpmFailure (121)
Name: InternalCommunicationProblem
Type: equipmentAlarm (3)
Probable cause:
internalCommunicationProblem (466)
Name: LagPortAddFailed
Type: equipmentAlarm (3)
Probable cause: linkDown (315)
Name: LanFailure
Type: equipmentAlarm (3)
Probable cause: lanFailure (467)
(10 of 14)
Alcatel-Lucent 5620 Service Aware Manager, Release
3HE 05723
AAAD
TQZZA Edition 01
Attributes
Severity: Critical
Object Type (class): FanTray
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): FanTray
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): BaseCard
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): DaughterCard
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): Equipment
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): Card
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Info
Object Type (class): Card
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Major
Object Type (class):
ControlProcessor
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): Equipment
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): Equipment
Domain: equipment
Implicitly cleared (self-clearing): Yes
8.0 R4
Aug 2010
Troubleshooting Guide
3 — Troubleshooting using network alarms
Additional information
The alarm is raised when the
associated fan is not operationally
up.
The alarm is raised when the
deviceState attribute has a value of
deviceNotEquipped.
The alarm is raised when the FIB
occupancy on an IOM card changes
from normal to high.
The alarm is raised when the FIB on
an MDA is out of synchronization.
The alarm is raised when a firmware
download is in progress.
The alarm is raised when a device
detects a mismatch between the
firmware version and the device
software image. The alarm
information includes the expected
firmware version.
The alarm is raised when a device
automatically upgrades the firmware
of a hot-inserted IOM or CPM.
The alarm is raised when the primary
CPM fails.
The alarm is raised when an ODU is
unresponsive.
The alarm is raised when the Lag Port
Add function Fails.
The alarm is raised when a LAN
failure is detected.