Alarm
Name: LowTemperatureThresholdCrossed
Type: environmentalAlarm (2)
Probable cause: equipmentOvercooled
(838)
Name: PowerSupplyVoltageAlarm
Type: equipmentAlarm (3)
Probable cause: powerSupplyFailure (117)
Name: RetimingBufferOverFlow
Type: communicationsAlarm (4)
Probable cause: bufferOverFlow (839)
Name: UnderlyingResourceUnavailable
Type: communicationsAlarm (4)
Probable cause:
underlyingResourceUnavailable (724)
Name: BackgroundDiagnosticFault
Type: equipmentAlarm (3)
Probable cause: backgroundDiagnosticFault
(353)
Name: BatmDsx1CurrentCSSs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Name: BatmDsx1CurrentESs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Name: BatmDsx1CurrentLESs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Name: BatmDsx1CurrentPVCs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Name: BatmDsx1CurrentSEFSs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
Name: BatmDsx1CurrentSESs
Type: thresholdCrossed (6)
Probable cause: thresholdCrossed (12)
(2 of 14)
Alcatel-Lucent 5620 Service Aware Manager, Release
3HE 05723
AAAD
TQZZA Edition 01
Attributes
Severity: Major
Object Type (class): Environment
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Info
Object Type (class): PowerSupply
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): ReplaceableUnit
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
8.0 R4
Aug 2010
Troubleshooting Guide
3 — Troubleshooting using network alarms
Additional information
The alarm is raised when a
temperature crosses a threshold.
The alarm is raised when the
associated power supply alarm
voltage state is not set to Normal.
The alarm is raised when an retiming
buffer overflow occurs.
The alarm is raised when an
underlying resource is unavailable on
an E1, radio, or Ethernet interface.
The alarm is raised when an NE
detects a failure in a background
diagnostic test suite.
The alarm is raised when the current
number of far-end Controlled Slip
Seconds crosses the threshold.
The alarm is raised when the current
number of far-end Errored Seconds
crosses the threshold.
The alarm is raised when the current
number of Line Errored Seconds
crosses the threshold.
The alarm is raised when the current
number of Path Coding Violations
crosses the threshold.
The alarm is raised when the current
number of far-end Severely Errored
Framing Seconds crosses the
threshold.
The alarm is raised when the current
number of far-end Severely Errored
Seconds crosses the threshold.