Trial Operation With Devicenet Communications - YASKAWA SGD7S Product Manual

E-7-series ac servo drive, e-7s servopack, command option attachable type with devicenet module
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

7.4

Trial Operation with DeviceNet Communications

A trial operation example for DeviceNet communications is given below.
Refer to the following chapter for details on commands.
Chapter 12 DeviceNet Functions
1.
Connect the DeviceNet communications connector (CN6 connector).
2.
Confirm that the wiring is correct, and then connect the I/O signal connector (CN1 con-
nector).
Refer to the following chapter for details on wiring.
Chapter 4 Wiring and Connections
3.
Turn ON the power supplies to the SERVOPACK.
If power is being supplied correctly, the CHARGE indicator on the SERVOPACK will light.
4.
Set the following items, which are necessary for trial operation.
Setting
Motor Direction
Feed Speed
Acceleration Rate
Deceleration Rate
Holding Brake
Motor Stopping
Method after Servo
OFF and Alarms
*
Set Pn507 for a Rotary Servomotor and Pn583 for a Linear Servomotor.
5.
Use DeviceNet I/O communications to perform positioning.
Refer to the following section for details on operation.
12.3 Positioning on page 12-6
6.
While operation is in progress for step 5, confirm the following items.
Confirm that the rotational direction of the
Servomotor agrees with the forward or
reverse reference. If they do not agree, cor-
rect the rotation direction of the Servomo-
tor.
Confirm that no abnormal vibration, noise,
or temperature rise occurs. If any abnor-
malities are found, implement corrections.
Note: If the load machine is not sufficiently broken in before trial operation, the Servomotor may become over-
loaded.
Parameters to Set
Pn000
PnB21
PnB26
PnB29
PnB2A
PnB2B
Pn506
Pn507 (Pn583)*
Pn508
Pn001
Pn00B
Confirmation Item

7.4 Trial Operation with DeviceNet Communications

Reference
5.4 Motor Direction Setting on page 5-17
12.3 Positioning on page 12-6
5.11 Holding Brake on page 5-31
5.12 Motor Stopping Method for Servo OFF and Alarms on
page 5-35
Reference
5.4 Motor Direction Setting on page 5-17
14.4 Troubleshooting Based on the Operation and Condi-
tions of the Servomotor on page 14-54