Applicable Tools; Operating Procedure - YASKAWA SGD7S Product Manual

E-7-series ac servo drive, e-7s servopack, command option attachable type with devicenet module
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

8.8.3

Applicable Tools

The following table lists the tools that you can use to perform custom tuning and the applicable
tool functions.
Tool
Digital Operator
SigmaWin+
8.8.4

Operating Procedure

Use the following procedure to perform custom tuning.
 Before you execute custom tuning, check the information provided in the SigmaWin+ oper-
ating manual.
Observe the following precautions.
• Make sure that you can perform an emergency stop at any time.
When custom tuning is started, several parameters will be overwritten with the recommended
settings, which may greatly affect the response before and after execution. Make sure that you
can perform an emergency stop at any time.
• Set the moment of inertia correctly before you execute custom tuning.
If the setting greatly differs from the actual moment of inertia, vibration may occur.
• If you change the feedforward level, the new setting will not be used immediately. It will be used
after positioning is completed.
1.
Confirm that the moment of inertia ratio (Pn103) is set correctly.
2.
Select Tuning - Tuning from the menu bar of the Main Window of the SigmaWin+.
Click the Cancel Button to cancel tuning.
3.
Click the Execute Button.
Function
Fn203
Tuning - Tuning
WARNING
8.8 Custom Tuning

8.8.3 Applicable Tools

Operating Procedure Reference
Σ-7-Series Digital Operator Operating
Manual (Manual No.: SIEP S800001 33)
8.8.4 Operating Procedure on page 8-43
8
8-43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca04aSgdv-oca05a

Table of Contents