7.3 Trial Operation for the Servomotor without a Load

7.3.1 Preparations

7.3

Trial Operation for the Servomotor without a Load

You use jogging for trial operation of the Servomotor without a load.
Jogging is used to check the operation of the Servomotor without connecting the SERVOPACK
to the host controller. The Servomotor is moved at the preset jogging speed.
7.3.1

Preparations

Always check the following before you execute jogging.
• The parameters must not be write prohibited.
• The main circuit power supply must be ON.
• There must be no alarms.
• There must be no hard wire base block (HWBB).
• The servo must be OFF.
• The jogging speed must be set considering the operating range of the machine.
The jogging speed is set with the following parameters.
• Rotary Servomotors
Pn304
Pn305
Pn306
• Direct Drive Servomotors
Pn304
Pn305
Pn306
• Linear Servomotors
Pn383
Pn305
Pn306
7-6
 During jogging, the overtravel function is disabled. Consider the range of motion of your
machine when you jog the Servomotor.
Jogging Speed
Setting Range
0 to 10,000
Soft Start Acceleration Time
Setting Range
0 to 10,000
Soft Start Deceleration Time
Setting Range
0 to 10,000
Jogging Speed
Setting Range
0 to 10,000
Soft Start Acceleration Time
Setting Range
0 to 10,000
Soft Start Deceleration Time
Setting Range
0 to 10,000
Jogging Speed
Setting Range
0 to 10,000
Soft Start Acceleration Time
Setting Range
0 to 10,000
Soft Start Deceleration Time
Setting Range
0 to 10,000
CAUTION
Setting Unit
Default Setting
-1
500
1 min
Setting Unit
Default Setting
1 ms
0
Setting Unit
Default Setting
1 ms
0
Setting Unit
Default Setting
-1
500
0.1 min
Setting Unit
Default Setting
1 ms
0
Setting Unit
Default Setting
1 ms
0
Setting Unit
Default Setting
1 mm/s
50
Setting Unit
Default Setting
1 ms
0
Setting Unit
Default Setting
1 ms
0
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup
When Enabled
Classification
Immediately
Setup

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca04aSgdv-oca05a

Table of Contents