5.1 Manipulating Parameters (Pn)

5.1.4 Write Prohibition Setting for Parameters

10.
Click the OK Button.
Information
11.
To enable changes to the settings, turn the power supply to the SERVOPACK OFF and
ON again.
This concludes the procedure to set the parameters.
Setting Parameters with a Digital Operator
Refer to the following manual for information on setting the parameters with a Digital Operator.
Σ-7-Series Digital Operator Operating Manual (Manual No.: SIEP S800001 33)
5.1.4

Write Prohibition Setting for Parameters

You can prohibit writing parameters from the Digital Operator.
Even if you do, you will still be able to change parameter settings from the SigmaWin+.
Preparations
No preparations are required.
Applicable Tools
The following table lists the tools that you can use to change the Write Prohibition Setting and
the applicable tool functions.
Digital Operator
SigmaWin+
Operating Procedure
Use the following procedure to prohibit or permit writing parameter settings.
1.
Select Setup - Write Prohibited Setting from the menu bar of the Main Window of the
SigmaWin+.
2.
Press the
0000: Writing is permitted (default setting).
0001: Writing is prohibited.
5-8
If you click the Cancel Button, you will return to the status before flash memory was writ-
ten.
Tool
Fn010
Setup - Write Prohibited Setting
or
for the rightmost digit and set one of the following.
Function
Reference
Σ-7-Series Digital Operator Operating
Manual (Manual No.: SIEP S800001
33)
Operating Procedure on page 5-8