Origin Returns; Origin Return Type; Parameter Settings - YASKAWA SGD7S Product Manual

E-7-series ac servo drive, e-7s servopack, command option attachable type with devicenet module
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

12.2

Origin Returns

An origin return must be performed after the power supply is turned ON to align the position of
the motor with the position of the machine. An origin return, however, is not required if an abso-
lute encoder is used.
12.2.1

Origin Return Type

The SERVOPACK supports the following three types of origin returns.

Origin Return Type

Type 0
Type 1
Type 3
Refer to the following section for details on origin returns.
13.3.3 Origin Returns on page 13-15
12.2.2

Parameter Settings

Connecting the Origin Signal Input
To use an origin return, wire the SERVOPACK CN1 connector pin that corresponds to the
switch for the origin signal input shown in the following table.
Type
Signal Name
Input
/HOME
Enabling/Disabling the Origin Signal Input
You can disable the origin signal input by changing the settings of a parameter in the SERVO-
PACK. If the input is disabled, wiring the origin signal input is not required.
 
b.
PnBA4
 
b.
Setting the Origin Signal Input Polarity
This parameter sets the polarity of the origin signal input that will be active.
 
b.
PnBA3
 
b.
An origin return is based on the Home Flag and the detection of phase C of the
encoder.
An origin return is based only on the Home Flag.
The axis travels at the origin approach speed in the specified origin return direc-
tion.
An origin return is based only on the detection of phase C of the encoder.
Connector Pin
CN1-11
Parameter
 
0
 
1
Parameter
 
0
 
1
Function
Meaning
Origin Signal Input
Meaning
The origin signal input is disabled.
The origin signal input (HOME) is input from CN1-11.
(Default setting)
Meaning
The origin signal input is active while the external switch is
open.
(Default setting)
With this setting, the position where the external switch
changes from closed to open will be the origin.
The origin signal input is active while the external switch is
closed.
With this setting, the position where the external switch
changes from open to closed will be the origin.

12.2 Origin Returns

12.2.1 Origin Return Type
12-3
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-oca04aSgdv-oca05a