Monitoring Product Life; Items That You Can Monitor - YASKAWA SGD7S Product Manual

E-7-series ac servo drive, e-7s servopack, command option attachable type with devicenet module
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

9.4 Monitoring Product Life

9.4.1 Items That You Can Monitor

9.4

Monitoring Product Life

9.4.1

Items That You Can Monitor

SERVOPACK Installation Envi-
ronment
Servomotor Installation Environ-
ment
Built-in Fan Service Life Predic-
tion
Capacitor Service Life Predic-
tion
Surge Prevention Circuit Ser-
vice Life Prediction
Dynamic Brake Circuit Service
Life Prediction
9-14
Monitor Item
The operating status of the SERVOPACK in terms of the installation envi-
ronment is displayed. Implement one or more of the following actions if the
monitor value exceeds 100%.
• Lower the surrounding temperature.
• Decrease the load.
The operating status of the SERVOPACK in terms of the installation envi-
ronment is displayed. Implement one or more of the following actions if the
monitor value exceeds 100%.
• Lower the surrounding temperature.
• Decrease the load.
The unused status of the SERVOPACK is treated as the 100% value. The
value decreases each time the main circuit power supply is turned ON and
each time the servo is turned OFF. Use a monitor value of 0% as a guideline
for the replacement period. Refer to the following section for part replace-
ment guidelines.
The unused status of the SERVOPACK is treated as the 100% value. The
value decreases each time the main circuit power supply is turned ON and
each time the servo is turned OFF. Use a monitor value of 0% as a guideline
for the replacement period. Refer to the following section for part replace-
ment guidelines.
The unused status of the SERVOPACK is treated as the 100% value. The
value decreases each time the main circuit power supply is turned ON and
each time the servo is turned OFF. Use a monitor value of 0% as a guideline
for the replacement period. Refer to the following section for part replace-
ment guidelines.
The unused status of the SERVOPACK is treated as the 100% value. The
value decreases each time the main circuit power supply is turned ON and
each time the servo is turned OFF. Use a monitor value of 0% as a guideline
for the replacement period. Refer to the following section for part replace-
ment guidelines.
Description
14.1.2 Guidelines for Part Replacement on page 14-2