6.6 Software Limits

6.6.1 Setting to Enable/Disable Software Limits

6.6

Software Limits

You can set limits in the software for machine movement that do not use the overtravel signals
(CCW-OT and CW-OT). If a software limit is exceeded, an emergency stop will be executed in
the same way as it is for overtravel.
You must make the following settings to use the software limits.
• You must enable the software limit function.
• You must set the software limits.
6.6.1

Setting to Enable/Disable Software Limits

You can use PnB18 (Software Limit Action Selection) to enable and disable the software limit
function.
The software limits are enabled at the following times:
• When an absolute encoder is used
• After completing an origin return when an incremental encoder is used
In all other cases, the software limit function will not operate even if a software limit is
exceeded.
PnB18
6.6.2

Setting the Software Limit Action

You can use PnB18 (Software Limit Action Selection) to set the stopping method when a soft-
ware limit is exceeded.
When a software limit is reached, the target position is automatically replaced with the current
position.
PnB18
6.6.3

Setting the Software Limits

Software limits are set in both the forward and reverse directions.
The reverse software limit must be less than the forward software limit to set a limit in each
direction.
PnB16
PnB17
6-16
Parameter
   
b.
   
b.
Parameter
   
b.
   
b.
Forward Software Limit
Setting Range
-2,147,483,647 to
2,147,483,647
Reverse Software Limit
Setting Range
-2,147,483,647 to
2,147,483,647
0
The software limits are disabled. (Default setting)
1
The software limits are enabled.
Meaning

0
Smooth stop (default setting)

1
Hard stop
Setting Unit
Default Setting
1 reference unit
2,147,483,647
Setting Unit
Default Setting
1 reference unit
-2,147,483,647
Meaning
When Enabled
Immediately
When Enabled
Immediately