The keys appear in the set order on the program monitor.
Changing the key priority for after the transition
1
In the M/E or PGM/PST menu, select first VF7 'Misc,' then HF4 'Next
Key Priority.'
The Next Key Priority menu appears.
2
For each of <Priority1>, <Priority2>, <Priority3>, and <Priority4>, select
a key, to determine the key priority sequence.
For details of the key priority sequence, see the figure shown for step 2 in
the previous item (see page 166).
The keys appear in the set order on the preview monitor.
3
Execute the transition.
The keys are rearranged in the set order on the program monitor.

Display of the Key Output Status and Key Priority

You can check whether keys are currently output, and the key priority setting,
using the key status display in the transition control block of the M/E or PGM/
PST bank.
The display is above the next transition selection buttons [KEY1] to [KEY4]
([DSK1] to [DSK4] buttons in the PGM/PST bank).
Notes
You can change the assignment of the next transition selection buttons [KEY1]
to [KEY4]. If this is changed, the output status and priority is shown for the
assigned key.
Display of the key output status
When a key is included in the output from the M/E or PGM/PST bank, the
corresponding ON indicator lights.
Key priority display
The key priority is indicated by numerals 1 to 4 lighting.
The topmost key as seen on the program monitor is priority 1, and the keys
underneath are numbered 2, 3, 4 away from the viewer (see page 166).