Sony MVE-9000-C Operation Manual

Sony MVE-9000-C Operation Manual

Dme processor pack; multi format dme processor
Hide thumbs Also See for MVE-9000-C:

Advertisement

Quick Links

DME PROCESSOR PACK
MVE-9000-C
MULTI FORMAT DME PROCESSOR
MVE-9000
MKE-9020M
MKE-9021M
OPERATION MANUAL
1st Edition (Revised 1)
MKE-9040M
HK-PSU04
[English]

Advertisement

Table of Contents
loading

Summary of Contents for Sony MVE-9000-C

  • Page 1 DME PROCESSOR PACK MVE-9000-C MULTI FORMAT DME PROCESSOR MVE-9000 MKE-9020M MKE-9021M MKE-9040M HK-PSU04 OPERATION MANUAL [English] 1st Edition (Revised 1)
  • Page 2 WARNING: THIS WARNING IS APPLICABLE FOR USA WARNING ONLY. To prevent fire or shock hazard, do not If used in USA, use the UL LISTED power cord specified expose the unit to rain or moisture. below. DO NOT USE ANY OTHER POWER CORD. To avoid electrical shock, do not open the Plug Cap Parallel blade with ground pin...
  • Page 3 For the customers in the USA Für Kunden in Europa (nur MVE-9000) This equipment has been tested and found to comply with the Dieses Produkt besitzt die CE-Kennzeichnung und erfüllt die limits for a Class A digital device, pursuant to Part 15 of the EMV-Richtlinie (89/336/EWG) sowie die FCC Rules.
  • Page 4 Ce produit est prévu pour être utilisé dans l’environnement électromagnétique suivant: E4 (environnement EMC contrôlé ex. studio de télévision). Periodic inspections To guarantee safe long-term operation, periodic inspections are recommended. Please contact your Sony representative for detailed information about the content and cost of periodic inspections.
  • Page 6: Table Of Contents

    Table of Contents Overview ................7 Features..................7 Overview of the MVE-9000-C Components......7 Location and Function of Parts........... 9 Front Panel................9 Rear Panel................10 Example System Configuration (MKE-9020M Installed) . 12 MVS-8000 System Configuration .......... 12 Flow of Video Signals ............13 Example System Configuration (MKE-9021M Installed) 14 MVS-8000 System Configuration ..........
  • Page 7: Overview

    DME wipes, processed keys and a wide variety of other System. DME effects to be used as if they were switcher functions. The MVE-9000-C is a generic name of the DME processor All DME operations can be controlled from the MVS-8000 unit having option boards installed in it.
  • Page 8 Optional accessories RMM-10 Rack Mount Kit Overview...
  • Page 9: Location And Function Of Parts

    Note If a status indicator does not light when you turn a POWER switch on, there may be a fault in the power circuits. Turn the POWER switch off and contact your Sony service representative. Location and Function of Parts...
  • Page 10: Rear Panel

    Rear Panel This figure shows the rear panel when one MKE-9020M is installed in the unit. 1SWITCHER A and B connectors SWITCHER A AC IN A SWITCHER B EXT IN MONI OUT AC IN B REMOTE4 REMOTE3 GPI 2 REMOTE2 REMOTE1 REF IN DATA...
  • Page 11 This network is used primarily to control the various devices from the center control panel. * Ethernet is a trademark of XEROX Corporation. For information about Ethernet switches that can be used in an MVS system, contact your Sony service representative. Location and Function of Parts...
  • Page 12: Example System Configuration (Mke-9020M Installed)

    Example System Configuration (MKE-9020M Installed) MVS-8000 System Configuration Reference video signal Ethernet switch Ethernet switch DATA REMOTE 1-4 MVE-9000-C DME CONTROL Processor Pack BVE-9100 Editing Control System Reference video signal CTRL DATA CTRL REMOTE 1 PERIPH REMOTE DATA MKS-8010 System...
  • Page 13: Flow Of Video Signals

    Flow of Video Signals MVE-9000-C DME Processor Pack SWITCHER A MONI OUT Monitor SWITCHER B EXT IN 100 to 240 V AC power supply Reference video signal Reference video signal DME 1B 100 to 240 V AC power supply 100 to 240 V AC power...
  • Page 14: Example System Configuration (Mke-9021M Installed)

    Example System Configuration (MKE-9021M Installed) MVS-8000 System Configuration Reference video signal Ethernet switch Ethernet switch DATA REMOTE 1-4 MVE-9000-C DME CONTROL Processor Pack BVE-9100 Editing Control System Reference video signal CTRL DATA CTRL REMOTE 1 PERIPH REMOTE DATA MKS-8010 System...
  • Page 15: Flow Of Video Signals

    Flow of Video Signals MVE-9000-C DME Processor Pack V. K OUT V. K IN/EXT IN 100 to 240 V AC power supply REF IN MONI OUT Reference video signal Monitor Reference video signal 100 to 240 V AC power supply...
  • Page 16: Power Supply Unit Status Indicator

    Power Supply Unit Status Indicator The power supply unit status indicator shows the status of the power supply unit during operation and when the unit is powered on. Whenever a power error is detected, it is reflected immediately by the indicator. Meaning of status indicator displays Indicator Status...
  • Page 17: Specifications

    Video output Specifications Outputs 4 (BNC type) Signal format HD: SMPTE 292M SD: SMPTE 259M-C Signal level 0.8Vp-p ±10% The following specifications show the reference performance for this unit and individual option boards. Signal transfer rate HD: 1.5Gbps SD: 270Mbps Design and specifications are subject to change without Return loss 15dB...
  • Page 18: Mke-9020M Mvs Interface Board

    Accessories not supplied MKE-9020M MVS Interface Board Operation and Installation Guide (1) (supplied only when product is purchased separately) General Power requirements MKE-9040M Advanced Effects Board 12 V DC Power consumption Power requirements Approx. 2 A 12 V DC Dimensions (w/d) Power consumption 278×94 mm Approx.
  • Page 19 The material contained in this manual consists of information that is the property of Sony Corporation and is intended solely for use by the purchasers of the equipment described in this manual. Sony Corporation expressly prohibits the duplication of any...
  • Page 20 Sony Corporation MVE-9000 Printed in Japan http://www.sony.net/ (WW) 2008.01.13 3-791-069-02 (1) © 2003 Printed on recycled paper...

This manual is also suitable for:

Mve-9000Mke-9020mMke-9021mMke-9040mHk-psu04

Table of Contents