Adjustment Of The Stop Position - SATO CW408 Operator's Manual

Table of Contents

Advertisement

Preliminary
Section 8: Appendix
8.4 BASE REFERENCE POINT ADJUSTMENT (Cont'd)

8.4.2 Adjustment of the Stop Position

Adjustment Location
Adjustment mode: Offset/ Cut position
The stop position for options (such as Cutter, Dispenser and Tear-off) is adjustable within the range of +3.75
mm to -3.75 mm (+0.15" to -0.15") using the adjustment LCD setting described above.
Adjustment for
Adjustment for
Note:
The above cutting position indicates the stop position when media sensor is set to Gap sensor.
The position for media in tear-off or dispense mode is adjustable in the same manner.
Adjustment requirements of stop position for various options are as follows:
Media Feed
Direction
Bottom Case
Perforation
Tear-Off Stop Position
Tear-off:
For perforated media, position of perforation should be +0 mm to +1.0 mm (+0" to +0.04") from
the edge of printer (Non-perforated media uses media center position as a reference.)
Dispenser: The label stop position from the dispenser is 2.0 mm ± 1.0 mm (0.08" ± 0.04").
Cutter:
For perforated media, cut the media after the perforation.
(For the non-perforated media, cut the center position +/- 0.5 mm (+/- 0.02") of the media.)
Page 8-6
Media feed direction
"+" value
No
Adjustment
"-" value
+3.75 mm (+0.15")
Within 1.0 mm (0.04")
Label
Adjustment Range
+3.75 mm to -3.75 mm (+0.15" to -0.15")
Base reference
point for printing
Cut position
(Print head)
24.0 mm
(0.95")
-3.75 mm (-0.15")
2.0 mm ±1.0 mm
Dispenser
(0.08" ± 0.04")
bar
Dispenser Stop Position
Within 1.0 mm (0.04")
Perforation
Label
Cutter Position
CW408 Operator Manual