SATO CW408 Operator's Manual page 67

Table of Contents

Advertisement

Preliminary
3.16 SERVICE MODE (Cont'd)
Menu
SENSOR ADJ(MAN)
GAP(R)
X.XV
SLICE LEVEL
1.4
V
SENSOR ADJ(MAN)
PAPER(R)
X.XV
ADJUST LEVEL
07
SENSOR ADJ(MAN)
PAPER(R)
X.XV
SLICE LEVEL
1.4
V
CW408 Operator Manual
SENSOR ADJUST MODE
Displays the current voltage of I-mark sensor on the upper part of the display.
The slice level is calculated automatically and displayed on the bottom line.
You can also adjust the slice level by pressing the LINE button.
The input range is 0.0V, and from 0.3V to 2.9V (adjustable in increments of
0.1V). The initial setting is 1.4V.
Notes:
The slice level is automatically set by firmware when the value is set to
0.0V.
In the case of automatic calculation, calculated value will be displayed auto-
matically after printing.
Press the FEED button to save the setting and move to the next screen.
Displays the current voltage of Paper sensor on the upper part of the display.
Adjust the light reception level of the Paper sensor with the LINE button. This
offset determines how soon the sensor will respond to incoming media.
The adjustment range is between 00 to 15 and is shown on the bottom line of
the display. The initial setting is 07.
Press the FEED button to save the setting and move to the next screen.
Displays the current voltage of Paper sensor on the upper part of the display.
The slice level is calculated automatically and displayed on the bottom line.
You can also adjust the slice level by pressing the LINE button.
The input range is 0.0V, and from 0.3V to 2.9V (adjustable in increments of
0.1V). The initial setting is 1.4V.
Notes:
The slice level is automatically set by firmware when the value is set to
0.0V.
In the case of automatic calculation, calculated value will be displayed auto-
matically after printing.
Press the FEED button to save the setting and move to the SERVICE MODE
menu.