5.1 ERROR SIGNAL TROUBLESHOOTING (Cont'd)
Error code
"cc" in error message shows cause of command error by code.
Code <cc>
01
Analyzed improper command
02
Received improper parameter
03
Analyzed improper graphic and external character data
04
(Not applicable for CW408 printer.)
05
Number specified by registration command is already taken
06
(Not applicable for CW408 printer.)
07
Data is not registered
08
Specified print start position is outside the printable area
99
Print rate of print data is high when using darkness range B.
Command error when Print darkness range is B
When using Print darkness range B and print ratio exceeds 50% (416 dots),
command error occurs because the print ratio is too high.
In this case, the screen message on the left is displayed.
Adjust print layout so that print ratio is under 50%.
CW408 Operator Manual
Cause
Section 5: Troubleshooting
ERROR27
INVALID DATA
C000:<AA>:99
Page 5-5