SATO CW408 Operator's Manual page 36

Table of Contents

Advertisement

Preliminary
Section 3: Operation and Configuration
3.4 ADJUSTMENT MODE (Cont'd)
Menu
ADJUSTMENT MODE
PITCH POSITION
+
0 . 0 0 mm
ADJUSTMENT MODE
OFFSET POSITION
+
0.00 mm
ADJUSTMENT MODE
CUT POSITION
+
0.0 0 mm
ADJUSTMENT MODE
PRINT DARKNESS
5
0
ADJUSTMENT MODE
BUZZER
ENABLE
DISABLE
ADJUSTMENT MODE
BRIGHTNESS
Page 3-10
Adjusts the print position or reference point where the printings begins verti-
cally, relative to the leading edge of each media.
Setting value is adjustable by 0.25 mm (0.01").
Setting range is ±3.75 mm (±0.15").
The initial value is +0.00 mm (+0.00").
Press the LINE button to set the value and press the FEED button to shift
the cursor to the next unit.
Adjust the offset (stop/ cut) position of each media after printing.
When the Operation mode is set as Continuous, Tear-off or Dispenser, OFF-
SET POSITION is displayed in this screen.
When the Operation mode is set as Cutter, CUT POSITION is displayed in
this screen.
Setting value is adjustable by 0.25 mm (0.01").
Setting range is ±3.75 mm (±0.15").
The initial value is +0.00 mm (+0.00").
Press the LINE button to set the value and press the FEED button to shift
the cursor to the next unit.
Adjust the print darkness of the printout.
Setting range is between 00 to 99.
The initial value is 50.
Press the LINE button to set the value and press the FEED button to shift
the cursor to the next unit.
Note:
It is not advisable to set the print darkness to the higher position as a darker
printout requires the print head to operate at higher temperatures. Operating
at high temperatures may reduce the serviceable lifetime of the print head.
Enable or disable the buzzer.
ENABLE: The buzzer will sound when an error occurs.
DISABLE: The buzzer will not sound.
The initial setting is ENABLE.
Press the LINE button to select and press the FEED button to save the set-
ting and proceed to the next adjustment screen.
Adjust the brightness of the display.
Setting range is 1 (dark) to 3 (bright).
The initial value is 2.
2
Press the LINE button to set the value and press the FEED button to shift
the cursor to the next unit.