Telnet Specifications; Setting/Displayed Items - SATO CW408 Operator's Manual

Table of Contents

Advertisement

Preliminary
Section 7: Interface Specifications
7.3 LOCAL AREA NETWORK (LAN) ETHERNET (Cont'd)

7.3.6 TELNET Specifications

TELNET complies with RFC854. This consists of an interactive menu form, and it enables you to change the
internal setup, refer to it and to display the status. To change the setting details, enter 'root' user name and
password at the time of login. Default value of root password is set to null (line feed only).
<Example of TELNET command>
In MS-DOS command prompt, type in [ TELNET xxx.xxx.xxx.xxx (IP address) ] and enter user name and
password to advance to the display below.
1) Printer name is entered in [ModelName].
2) For the detailed settings of [1:Setup TCP/IP], refer to Section 7.3.7 Setting/Displayed Items.

7.3.7 Setting/Displayed Items

The following table shows the settings and referable sections as well as various variables.
TCP/IP related setting
Variable Identifier
IP address
Subnet mask
Gateway address
RARP protocol
DHCP protocol
Keepalive time
Keepalive retry
Socket cancel
ROOT password
1
*
Number in [ ] is the limit number of characters.
Page 7-6
SATO PRINTER [ModelName] TELNET server.
Copyright 2011(C) SATO Corporation.
login: root
'root' user needs password to login.
password:
User 'root' logged in
No. Item
----------------------------------------------------------
1 : Setup TCP/IP
2 : Display status
99 : Exit setup
Please select(1-99)?
Setting Range
0.0.0.0 ~ 255.255.255.255
0.0.0.0 ~ 255.255.255.255
0.0.0.0 ~ 255.255.255.255
ENABLE/ DISABLE
ENABLE/ DISABLE
30~300
1~99
Normal/Compatible
Any alphanumeric characters[16]*
Value
(level.1)
Default (Factory Setting)
192.168.1.1
255.255.255.0(Calculated from IP
address)
0.0.0.0
DISABLE
DISABLE
180 (Sec)
17 (Times)
Normal
1
NULL (No password)
CW408 Operator Manual